- differential pressure now processed downstream like other sensor data (accel/gyro/mag/etc)
- rename msg differential_pressure -> sensor_differential_pressure
- add device id and timestamp_sample to all messages
- calibration performend directly on raw data and SENS_DPRES_OFF parameter updated
- remove Airspeed base class from existing differential pressure drivers
- name differential pressure drivers consistently (no _airspeed suffix)
* FW attitude controller, FW position controller and VTOL attitude controller subscribe to airspeed_validated topic
* add possibility to switch off the airspeed valid checks
* remove airspeed valid checks from commander
* clean up of VTOL transition logic
* Airspeed Selector: remove dynamic allocation of airspeed validators (depending on number of connected sensors) but do it statically for the maximum number allowed. Check for number of connected sensors not only during start up, but always when vehicle is disarmed.
* Airspeed Selector: change work queue from lp to att_pos_ctrl as this module is safety-critical
* add airspeed selector to px4_fmu-v2 defaults
This new airspeed module does:
-runns an airspeed validator for every airspeed sensor present, which checks measurement validity and estimates an airspeed scale
-selects another airspeed sensor if for the current one a failure is detected
-estimates airspeed with groundspeed-windspeed if no valid airspeed sensor is present
-outputs airspeed_validated topic
Signed-off-by: Silvan Fuhrer <silvan@auterion.com>