batterry_status: fix checking default v_div

This commit is contained in:
Oleg
2020-08-30 11:59:16 +03:00
committed by Daniel Agar
parent 9feea0e2fd
commit 172a4e3557
@@ -105,7 +105,7 @@ AnalogBattery::updateParams()
param_get(_analog_param_handles.i_channel, &_analog_params.i_channel);
param_get(_analog_param_handles.v_offs_cur, &_analog_params.v_offs_cur);
if (_analog_params.v_div <= 0.0f) {
if (_analog_params.v_div < 0.0f) {
/* apply scaling according to defaults if set to default */
_analog_params.v_div = BOARD_BATTERY1_V_DIV;
param_set_no_notification(_analog_param_handles.v_div, &_analog_params.v_div);