mirror of
https://gitlab.rtems.org/rtems/rtos/rtems.git
synced 2026-11-16 19:04:53 +08:00
testsuites/sptests: Bound the timecounter error
The job runs for a number of clock ticks, so the measured duration is quantised to the tick period. The test required the difference from the nominal one second to stay below a millisecond, which can only hold where the clock tick is shorter than that. With the default tick of ten milliseconds it passes by luck. It failed on the mips simulator. Allow one clock tick and a millisecond for the granularity of the loop which observes the stop condition. Update #5710. Assisted-by: Claude:claude-opus-5 claude-code Signed-off-by: Sebastian Huber <sebastian.huber@embedded-brains.de>
This commit is contained in:
1 parent
262b9756c7
commit
4db6143bd2
1 file changed
+10
-1
@@ -183,9 +183,18 @@ static void test_bintime_fini(
|
||||
|
||||
for ( i = 0; i < active_workers; ++i ) {
|
||||
sbintime_t error;
|
||||
sbintime_t limit;
|
||||
|
||||
/*
|
||||
* The job runs for a number of clock ticks, so the measured duration is
|
||||
* quantised to the tick period. A limit of one millisecond only holds
|
||||
* where the tick is shorter than that. Allow one tick and a millisecond
|
||||
* for the granularity of the loop which observes the stop condition.
|
||||
*/
|
||||
limit = SBT_1S / (sbintime_t) rtems_clock_get_ticks_per_second() + SBT_1MS;
|
||||
|
||||
error = DURATION_IN_SECONDS * SBT_1S - ctx->duration_per_job[ i ];
|
||||
rtems_test_assert( error * error < SBT_1MS * SBT_1MS );
|
||||
rtems_test_assert( error * error < limit * limit );
|
||||
}
|
||||
|
||||
test_print_results( "Clock Driver", ctx, active_workers );
|
||||
|
||||
Reference in new issue
Block a user