wangjianyu3 c100e9a9e8 esp_i2s: use actual channel count for BCLK calculation
The I2S BCLK frequency is calculated as:
  bclk = sample_rate * total_slot * data_width

Previously, total_slot was always taken from the static config
(esp_i2s0_config / esp_i2s1_config), which is hardcoded to 2.
This is correct for mono and stereo, but wrong for TDM modes
with more than 2 channels (e.g. 4-channel recording with ES7210).

With 4 channels but total_slot=2, the BCLK is only half of what
it should be, causing the actual sample rate to be half of the
requested rate (e.g. requesting 16 kHz actually samples at 8 kHz).

Replace priv->config->total_slot with MAX(priv->channels, 2) in
all three BCLK calculation sites (i2s_check_mclkfrequency and
i2s_set_clock for both master and slave paths). The MIN of 2
preserves the I2S protocol requirement that at least 2 slots
exist even for mono, while correctly scaling for multi-channel
TDM configurations.

Signed-off-by: wangjianyu3 <wangjianyu3@xiaomi.com>