driver for SIM7600 LTE modems
--]]
local MAV_SEVERITY = {EMERGENCY=0, ALERT=1, CRITICAL=2, ERROR=3, WARNING=4, NOTICE=5, INFO=6, DEBUG=7}
local PARAM_TABLE_KEY = 106
local PARAM_TABLE_PREFIX = "LTE_"
-- local MAVLINK2 = 2
local PPP = 48
-- add a parameter and bind it to a variable
local function bind_add_param(name, idx, default_value)
assert(param:add_param(PARAM_TABLE_KEY, idx, name, default_value), string.format('could not add param %s', name))
return Parameter(PARAM_TABLE_PREFIX .. name)
end
-- Setup Parameters
assert(param:add_table(PARAM_TABLE_KEY, PARAM_TABLE_PREFIX, 20), 'SIM7600: could not add param table')
--[[
// @Param: LTE_ENABLE
// @DisplayName: LTE Enable
// @Description: Enable or disable the LTE modem driver
// @Values: 0:Disabled,1:Enabled
// @User: Standard
--]]
local LTE_ENABLE = bind_add_param('ENABLE', 1, 1)
--[[
// @Param: LTE_SERPORT
// @DisplayName: Serial Port
// @Description: Serial port to use for the LTE modem. This is the index of the SERIALn_ ports that are set to 28 for "scripting"
// @Range: 0 8
// @User: Standard
--]]
local LTE_SERPORT = bind_add_param('SERPORT', 2, 0)
--[[
// @Param: LTE_SCRPORT
// @DisplayName: Scripting Serial Port
// @Description: Scripting Serial port to use for the LTE modem. This is the index of the SCR_SDEV ports that are set to 2 for "MAVLink2"
// @Range: 0 8
// @User: Standard
--]]
local LTE_SCRPORT = bind_add_param('SCRPORT', 3, 0)
--[[
// @Param: LTE_SERVER_IP0
// @DisplayName: Server IP 0
// @Description: First octet of the server IP address to connect to
// @Range: 0 255
// @User: Standard
--]]
local LTE_SERVER_IP0 = bind_add_param('SERVER_IP0', 4, 0)
--[[
// @Param: LTE_SERVER_IP1
// @DisplayName: Server IP 1
// @Description: Second octet of the server IP address to connect to
// @Range: 0 255
// @User: Standard
--]]
local LTE_SERVER_IP1 = bind_add_param('SERVER_IP1', 5, 0)
--[[
// @Param: LTE_SERVER_IP2
// @DisplayName: Server IP 2
// @Description: Third octet of the server IP address to connect to
// @Range: 0 255
// @User: Standard
--]]
local LTE_SERVER_IP2 = bind_add_param('SERVER_IP2', 6, 0)
--[[
// @Param: LTE_SERVER_IP3
// @DisplayName: Server IP 3
// @Description: Fourth octet of the server IP address to connect to
// @Range: 0 255
// @User: Standard
--]]
local LTE_SERVER_IP3 = bind_add_param('SERVER_IP3', 7, 0)
--[[
// @Param: LTE_SERVER_PORT
// @DisplayName: Server Port
// @Description: IPv4 Port of the server to connect to
// @Range: 1 65525
// @User: Standard
--]]
local LTE_SERVER_PORT = bind_add_param('SERVER_PORT', 8, 0)
--[[
// @Param: LTE_BAUD
// @DisplayName: Serial Baud Rate
// @Description: Baud rate for the serial port to the LTE modem. If using something other than 115200 you need to connect to the modem and use AT+IPREX=BAUD to set the baud rate and save with AT&W. The fastest supported baudrate is 3686400.
// @Values: 19200:19200,38400:38400,57600:57600,115200:115200,230400:230400,460800:460800,921600:921600,3686400:3686400
// @User: Standard
--]]
local LTE_BAUD = bind_add_param('BAUD', 9, 115200)
--[[
// @Param: LTE_TIMEOUT
// @DisplayName: Timeout
// @Description: Timeout in seconds for the LTE connection. If no data is received for this time, the connection will be reset.
// @Range: 1 60
// @Units: s
// @User: Standard
--]]
local LTE_TIMEOUT = bind_add_param('TIMEOUT', 10, 10)
--[[
// @Param: LTE_PROTOCOL
// @DisplayName: LTE protocol
// @Description: The protocol that we will use in communication with the LTE modem. If this is PPP then the LTE_SERVER parameters are not used and instead a PPP connection will be established and you should use the NET_ parameters to enable network ports. If this is MAVLink2 then the LTE_SERVER parameters are used to create a TCP connection to a single TCP server.
// @Values: 2:MavLink2,48:PPP
// @User: Standard
--]]
local LTE_PROTOCOL = bind_add_param('PROTOCOL', 11, 48)
local uart = serial:find_serial(LTE_SERPORT:get())
if not uart then
gcs:send_text(MAV_SEVERITY.ERROR, 'SIM7600: could not find serial port')
return
end
local ser_device = serial:find_simulated_device(LTE_PROTOCOL:get(), LTE_SCRPORT:get())
if not ser_device then
gcs:send_text(MAV_SEVERITY.ERROR, 'SIM7600: could not find SCR_SDEV device')
return
end
local step = "ATI"
uart:begin(LTE_BAUD:get())
--[[
Open a log file to log the output from the modem
This is useful for debugging the connection process
--]]
local log_file = io.open('SIM7600.log', 'w')
--[[
Function to read from the UART and log the output
This function reads up to 512 bytes at a time and writes it to the log file
returns the string read or nil
--]]
local function uart_read()
local s = uart:readstring(512)
if s and #s > 0 and log_file then
log_file:write('[' .. s .. ']\n')
log_file:flush()
end
return s
end
--[[
Function to handle errors in the response from the modem
If an error is detected, it resets the modem
returns true if an error was detected
--]]
local function handle_error(s)
if s and s:find('\nERROR\r\n') then
gcs:send_text(MAV_SEVERITY.ERROR, 'SIM7600: error response from modem')
uart:writestring('AT+CRESET\r\n')
step = "ATI"
return true
end
return false
end
local ati_sequence = 0
--[[
Function to confirm the connection to the modem
it uses AIT command to get the modem info, and +++ if needed
to break out of transparent mode
--]]
local function step_ATI()
local s = uart_read()
if s and s:find('IMEI: ') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: found modem')
step = "CREG"
return
end
if ati_sequence == 1 then
uart:writestring('+++')
ati_sequence = 0
else
uart:writestring('\r\nATI\r\n')
ati_sequence = 1
end
end
--[[
confirm we are registered on the network
--]]
local function step_CREG()
local s = uart_read()
if handle_error(s) then
return
end
if s and s:find('CREG: 0,1\r\n') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: CREG OK')
if LTE_PROTOCOL:get() == PPP then
step = "PPPOPEN"
else
step = "CIPMODE"
end
return
end
uart:writestring('AT+CREG?\r\n')
end
--[[
set the modem to transparent mode
--]]
local function step_CIPMODE()
local s = uart_read()
if handle_error(s) then
return
end
if s and s:find('CIPMODE=1\r\r\nOK\r') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: transparent mode set')
step = "NETOPEN"
return
end
uart:writestring('AT+CIPMODE=1\r\n')
end
--[[
open the network stack
needed to be able to open a TCP connection
--]]
local function step_NETOPEN()
local s = uart_read()
if handle_error(s) then
return
end
if s and s:find('NETOPEN\r\r\nOK\r\n') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: network opened')
step = "CIPOPEN"
return
end
uart:writestring('AT+NETOPEN\r\n')
end
local last_data_ms = millis()
local pending_to_modem = ""
local pending_to_fc = ""
--[[
open PPP mode
--]]
local function step_PPPOPEN()
local s = uart_read()
if handle_error(s) then
return
end
if s and s:find('CONNECT ') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: connected')
last_data_ms = millis()
pending_to_modem = ""
pending_to_fc = ""
step = "CONNECTED"
return
end
uart:writestring(string.format('AT+CGDATA="PPP",1\r\n'))
end
--[[
open a TCP connection to the server
the server IP and port are defined in the parameters
--]]
local function step_CIPOPEN()
local s = uart_read()
if handle_error(s) then
return
end
if s and s:find('CONNECT ') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: connected')
last_data_ms = millis()
pending_to_modem = ""
pending_to_fc = ""
step = "CONNECTED"
return
end
if LTE_SERVER_PORT:get() <= 0 then
gcs:send_text(MAV_SEVERITY.ERROR, "Must set LTE_SERVER_PORT")
return
end
uart:writestring(string.format('AT+CIPOPEN=0,"TCP","%d.%d.%d.%d",%d\r\n',
LTE_SERVER_IP0:get(), LTE_SERVER_IP1:get(), LTE_SERVER_IP2:get(), LTE_SERVER_IP3:get(),
LTE_SERVER_PORT:get()))
end
--[[
handle data while connected
--]]
local function step_CONNECTED()
local s = uart:readstring(512)
if s and s:find('\r\nCLOSED\r\n') then
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: connection closed, reconnecting')
step = "CIPOPEN"
return
end
local now_ms = millis()
if s and #s > 0 then
last_data_ms = now_ms
pending_to_fc = pending_to_fc .. s
elseif now_ms - last_data_ms > uint32_t(LTE_TIMEOUT:get() * 1000) then
gcs:send_text(MAV_SEVERITY.ERROR, 'SIM7600: timeout')
step = "ATI"
return
end
s = ser_device:readstring(512)
if s then
pending_to_modem = pending_to_modem .. s
end
--[[
going via these pending buffers allows for rapid bursts of data and takes advantage
of the hardware flow control
--]]
local buffer_limit = 10240 -- so we don't run out of memory
if #pending_to_modem > buffer_limit then
pending_to_modem = ""
end
if #pending_to_fc > buffer_limit then
pending_to_fc = ""
end
if #pending_to_modem > 0 then
local nwritten = uart:writestring(pending_to_modem)
if nwritten > 0 then
pending_to_modem = pending_to_modem:sub(nwritten + 1)
end
end
if #pending_to_fc > 0 then
local nwritten = ser_device:writestring(pending_to_fc)
if nwritten > 0 then
pending_to_fc = pending_to_fc:sub(nwritten + 1)
end
end
end
local function update()
if LTE_ENABLE:get() == 0 then
return update, 500
end
if step == "CONNECTED" then
-- run the connected step at 200Hz
step_CONNECTED()
return update, 5
end
gcs:send_text(MAV_SEVERITY.INFO, string.format('SIM7600: step %s', step))
if step == "ATI" then
step_ATI()
return update, 1100
end
if step == "CREG" then
step_CREG()
return update, 500
end
if step == "CIPMODE" then
step_CIPMODE()
return update, 500
end
if step == "NETOPEN" then
step_NETOPEN()
return update, 500
end
if step == "PPPOPEN" then
step_PPPOPEN()
return update, 500
end
if step == "CIPOPEN" then
step_CIPOPEN()
return update, 500
end
gcs:send_text(MAV_SEVERITY.ERROR, string.format("SIM7600: bad step %s", step))
step = "ATI"
end
gcs:send_text(MAV_SEVERITY.INFO, 'SIM7600: starting')
return update,500