GeneratorStatus (UORB message)

TOPICS: generator_status

Fields

Name Type Unit [Frame] Range/Enum Description
timestamp uint64 time since system start (microseconds)
status uint64 Status flags
battery_current float32 A Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
load_current float32 A Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
power_generated float32 W The power being generated. NaN: field not provided
bus_voltage float32 V Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
bat_current_setpoint float32 A The target battery current. Positive for out. Negative for in. NaN: field not provided
runtime uint32 s Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.
time_until_maintenance int32 s Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.
generator_speed uint16 rpm Speed of electrical generator or alternator. UINT16_MAX: field not provided.
rectifier_temperature int16 degC The temperature of the rectifier or power converter. INT16_MAX: field not provided.
generator_temperature int16 degC The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.

Constants

Name Type Value Description
STATUS_FLAG_OFF uint64 1 Generator is off.
STATUS_FLAG_READY uint64 2 Generator is ready to start generating power.
STATUS_FLAG_GENERATING uint64 4 Generator is generating power.
STATUS_FLAG_CHARGING uint64 8 Generator is charging the batteries (generating enough power to charge and provide the load).
STATUS_FLAG_REDUCED_POWER uint64 16 Generator is operating at a reduced maximum power.
STATUS_FLAG_MAXPOWER uint64 32 Generator is providing the maximum output.
STATUS_FLAG_OVERTEMP_WARNING uint64 64 Generator is near the maximum operating temperature, cooling is insufficient.
STATUS_FLAG_OVERTEMP_FAULT uint64 128 Generator hit the maximum operating temperature and shutdown.
STATUS_FLAG_ELECTRONICS_OVERTEMP_WARNING uint64 256 Power electronics are near the maximum operating temperature, cooling is insufficient.
STATUS_FLAG_ELECTRONICS_OVERTEMP_FAULT uint64 512 Power electronics hit the maximum operating temperature and shutdown.
STATUS_FLAG_ELECTRONICS_FAULT uint64 1024 Power electronics experienced a fault and shutdown.
STATUS_FLAG_POWERSOURCE_FAULT uint64 2048 The power source supplying the generator failed e.g. mechanical generator stopped, tether is no longer providing power, solar cell is in shade, hydrogen reaction no longer happening.
STATUS_FLAG_COMMUNICATION_WARNING uint64 4096 Generator controller having communication problems.
STATUS_FLAG_COOLING_WARNING uint64 8192 Power electronic or generator cooling system error.
STATUS_FLAG_POWER_RAIL_FAULT uint64 16384 Generator controller power rail experienced a fault.
STATUS_FLAG_OVERCURRENT_FAULT uint64 32768 Generator controller exceeded the overcurrent threshold and shutdown to prevent damage.
STATUS_FLAG_BATTERY_OVERCHARGE_CURRENT_FAULT uint64 65536 Generator controller detected a high current going into the batteries and shutdown to prevent battery damage.
STATUS_FLAG_OVERVOLTAGE_FAULT uint64 131072 Generator controller exceeded it's overvoltage threshold and shutdown to prevent it exceeding the voltage rating.
STATUS_FLAG_BATTERY_UNDERVOLT_FAULT uint64 262144 Batteries are under voltage (generator will not start).
STATUS_FLAG_START_INHIBITED uint64 524288 Generator start is inhibited by e.g. a safety switch.
STATUS_FLAG_MAINTENANCE_REQUIRED uint64 1048576 Generator requires maintenance.
STATUS_FLAG_WARMING_UP uint64 2097152 Generator is not ready to generate yet.
STATUS_FLAG_IDLE uint64 4194304 Generator is idle.

Source Message

Source file (GitHub)

::: details Click here to see original file

uint64 timestamp			# time since system start (microseconds)


uint64 STATUS_FLAG_OFF                              = 1       # Generator is off.
uint64 STATUS_FLAG_READY                            = 2       # Generator is ready to start generating power.
uint64 STATUS_FLAG_GENERATING                       = 4       # Generator is generating power.
uint64 STATUS_FLAG_CHARGING                         = 8       # Generator is charging the batteries (generating enough power to charge and provide the load).
uint64 STATUS_FLAG_REDUCED_POWER                    = 16      # Generator is operating at a reduced maximum power.
uint64 STATUS_FLAG_MAXPOWER                         = 32      # Generator is providing the maximum output.
uint64 STATUS_FLAG_OVERTEMP_WARNING                 = 64      # Generator is near the maximum operating temperature, cooling is insufficient.
uint64 STATUS_FLAG_OVERTEMP_FAULT                   = 128     # Generator hit the maximum operating temperature and shutdown.
uint64 STATUS_FLAG_ELECTRONICS_OVERTEMP_WARNING     = 256     # Power electronics are near the maximum operating temperature, cooling is insufficient.
uint64 STATUS_FLAG_ELECTRONICS_OVERTEMP_FAULT       = 512     # Power electronics hit the maximum operating temperature and shutdown.
uint64 STATUS_FLAG_ELECTRONICS_FAULT                = 1024    # Power electronics experienced a fault and shutdown.
uint64 STATUS_FLAG_POWERSOURCE_FAULT                = 2048    # The power source supplying the generator failed e.g. mechanical generator stopped, tether is no longer providing power, solar cell is in shade, hydrogen reaction no longer happening.
uint64 STATUS_FLAG_COMMUNICATION_WARNING            = 4096    # Generator controller having communication problems.
uint64 STATUS_FLAG_COOLING_WARNING                  = 8192    # Power electronic or generator cooling system error.
uint64 STATUS_FLAG_POWER_RAIL_FAULT                 = 16384   # Generator controller power rail experienced a fault.
uint64 STATUS_FLAG_OVERCURRENT_FAULT                = 32768   # Generator controller exceeded the overcurrent threshold and shutdown to prevent damage.
uint64 STATUS_FLAG_BATTERY_OVERCHARGE_CURRENT_FAULT = 65536   # Generator controller detected a high current going into the batteries and shutdown to prevent battery damage. |
uint64 STATUS_FLAG_OVERVOLTAGE_FAULT                = 131072  # Generator controller exceeded it's overvoltage threshold and shutdown to prevent it exceeding the voltage rating.
uint64 STATUS_FLAG_BATTERY_UNDERVOLT_FAULT          = 262144  # Batteries are under voltage (generator will not start).
uint64 STATUS_FLAG_START_INHIBITED                  = 524288  # Generator start is inhibited by e.g. a safety switch.
uint64 STATUS_FLAG_MAINTENANCE_REQUIRED             = 1048576 # Generator requires maintenance.
uint64 STATUS_FLAG_WARMING_UP                       = 2097152 # Generator is not ready to generate yet.
uint64 STATUS_FLAG_IDLE                             = 4194304 # Generator is idle.

uint64 status                      # Status flags


float32 battery_current            # [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
float32 load_current               # [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
float32 power_generated            # [W] The power being generated. NaN: field not provided
float32 bus_voltage                # [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
float32 bat_current_setpoint       # [A] The target battery current. Positive for out. Negative for in. NaN: field not provided

uint32 runtime                     # [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.

int32 time_until_maintenance       # [s] Seconds until this generator requires maintenance.  A negative value indicates maintenance is past-due. INT32_MAX: field not provided.

uint16 generator_speed             # [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.

int16 rectifier_temperature        # [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.
int16 generator_temperature        # [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.

:::