Simplify Battery-related Enum Naming (#24265)

* Simplify battery-related enum naming

* Fix mistakenly removed string in enum names

* Fix missing renamings

* Update outdated file

* msg: Increase battery_status version since the enum naming was changed

* Revert message version increase

---------

Co-authored-by: Matthias Grob <maetugr@gmail.com>
This commit is contained in:
Sebastian Domoszlai
2025-02-28 21:42:40 +01:00
committed by GitHub
parent 336d055923
commit b5f37c9fa6
25 changed files with 101 additions and 101 deletions
+22 -22
View File
@@ -12,9 +12,9 @@ float32 time_remaining_s # predicted time in seconds remaining until battery i
float32 temperature # Temperature of the battery in degrees Celcius, NaN if unknown
uint8 cell_count # Number of cells, 0 if unknown
uint8 BATTERY_SOURCE_POWER_MODULE = 0
uint8 BATTERY_SOURCE_EXTERNAL = 1
uint8 BATTERY_SOURCE_ESCS = 2
uint8 SOURCE_POWER_MODULE = 0
uint8 SOURCE_EXTERNAL = 1
uint8 SOURCE_ESCS = 2
uint8 source # Battery source
uint8 priority # Zero based priority is the connection on the Power Controller V1..Vn AKA BrickN-1
uint16 capacity # actual capacity of the battery
@@ -34,26 +34,26 @@ bool is_powering_off # Power off event imminent indication, false if unknown
bool is_required # Set if the battery is explicitly required before arming
uint8 BATTERY_WARNING_NONE = 0 # no battery low voltage warning active
uint8 BATTERY_WARNING_LOW = 1 # warning of low voltage
uint8 BATTERY_WARNING_CRITICAL = 2 # critical voltage, return / abort immediately
uint8 BATTERY_WARNING_EMERGENCY = 3 # immediate landing required
uint8 BATTERY_WARNING_FAILED = 4 # the battery has failed completely
uint8 BATTERY_STATE_UNHEALTHY = 6 # Battery is diagnosed to be defective or an error occurred, usage is discouraged / prohibited. Possible causes (faults) are listed in faults field.
uint8 BATTERY_STATE_CHARGING = 7 # Battery is charging
uint8 WARNING_NONE = 0 # no battery low voltage warning active
uint8 WARNING_LOW = 1 # warning of low voltage
uint8 WARNING_CRITICAL = 2 # critical voltage, return / abort immediately
uint8 WARNING_EMERGENCY = 3 # immediate landing required
uint8 WARNING_FAILED = 4 # the battery has failed completely
uint8 STATE_UNHEALTHY = 6 # Battery is diagnosed to be defective or an error occurred, usage is discouraged / prohibited. Possible causes (faults) are listed in faults field.
uint8 STATE_CHARGING = 7 # Battery is charging
uint8 BATTERY_FAULT_DEEP_DISCHARGE = 0 # Battery has deep discharged
uint8 BATTERY_FAULT_SPIKES = 1 # Voltage spikes
uint8 BATTERY_FAULT_CELL_FAIL= 2 # One or more cells have failed
uint8 BATTERY_FAULT_OVER_CURRENT = 3 # Over-current
uint8 BATTERY_FAULT_OVER_TEMPERATURE = 4 # Over-temperature
uint8 BATTERY_FAULT_UNDER_TEMPERATURE = 5 # Under-temperature fault
uint8 BATTERY_FAULT_INCOMPATIBLE_VOLTAGE = 6 # Vehicle voltage is not compatible with this battery (batteries on same power rail should have similar voltage).
uint8 BATTERY_FAULT_INCOMPATIBLE_FIRMWARE = 7 # Battery firmware is not compatible with current autopilot firmware
uint8 BATTERY_FAULT_INCOMPATIBLE_MODEL = 8 # Battery model is not supported by the system
uint8 BATTERY_FAULT_HARDWARE_FAILURE = 9 # hardware problem
uint8 BATTERY_FAULT_FAILED_TO_ARM = 10 # Battery had a problem while arming
uint8 BATTERY_FAULT_COUNT = 11 # Counter - keep it as last element!
uint8 FAULT_DEEP_DISCHARGE = 0 # Battery has deep discharged
uint8 FAULT_SPIKES = 1 # Voltage spikes
uint8 FAULT_CELL_FAIL= 2 # One or more cells have failed
uint8 FAULT_OVER_CURRENT = 3 # Over-current
uint8 FAULT_OVER_TEMPERATURE = 4 # Over-temperature
uint8 FAULT_UNDER_TEMPERATURE = 5 # Under-temperature fault
uint8 FAULT_INCOMPATIBLE_VOLTAGE = 6 # Vehicle voltage is not compatible with this battery (batteries on same power rail should have similar voltage).
uint8 FAULT_INCOMPATIBLE_FIRMWARE = 7 # Battery firmware is not compatible with current autopilot firmware
uint8 FAULT_INCOMPATIBLE_MODEL = 8 # Battery model is not supported by the system
uint8 FAULT_HARDWARE_FAILURE = 9 # hardware problem
uint8 FAULT_FAILED_TO_ARM = 10 # Battery had a problem while arming
uint8 FAULT_COUNT = 11 # Counter - keep it as last element!
uint16 faults # Smart battery supply status/fault flags (bitmask) for health indication.
uint8 warning # Current battery warning