fix(vertiq): Parameter Setting Reliability Update (#26521)
Updates to the backend to allow faster and more reliable parameter configuration. --------- Co-authored-by: Jordan <jordan.leiber@vertiq.co>
This commit is contained in:
@@ -35,7 +35,18 @@
|
|||||||
VertiqConfigurationHandler::VertiqConfigurationHandler(VertiqSerialInterface *ser,
|
VertiqConfigurationHandler::VertiqConfigurationHandler(VertiqSerialInterface *ser,
|
||||||
VertiqClientManager *client_manager) :
|
VertiqClientManager *client_manager) :
|
||||||
_serial_interface(ser),
|
_serial_interface(ser),
|
||||||
_client_manager(client_manager)
|
_client_manager(client_manager),
|
||||||
|
_prop_input_parser_client(0)
|
||||||
|
|
||||||
|
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
||||||
|
, _ifci_client(0)
|
||||||
|
#endif
|
||||||
|
|
||||||
|
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
||||||
|
, _voltage_superposition_client(0)
|
||||||
|
, _pulsing_rectangular_input_parser_client(0)
|
||||||
|
#endif
|
||||||
|
|
||||||
{
|
{
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -43,47 +54,47 @@ void VertiqConfigurationHandler::InitConfigurationClients(uint8_t object_id)
|
|||||||
{
|
{
|
||||||
_object_id_now = object_id; //Make sure we store the initial object ID
|
_object_id_now = object_id; //Make sure we store the initial object ID
|
||||||
|
|
||||||
_prop_input_parser_client = new EscPropellerInputParserClient(object_id);
|
_prop_input_parser_client.UpdateEntryIds(object_id);
|
||||||
_client_manager->AddNewClient(_prop_input_parser_client);
|
_client_manager->AddNewClient(&_prop_input_parser_client);
|
||||||
|
|
||||||
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
||||||
_ifci_client = new IQUartFlightControllerInterfaceClient(object_id);
|
_ifci_client.UpdateEntryIds(object_id);
|
||||||
_client_manager->AddNewClient(_ifci_client);
|
_client_manager->AddNewClient(&_ifci_client);
|
||||||
#endif //CONFIG_USE_IFCI_CONFIGURATION
|
#endif //CONFIG_USE_IFCI_CONFIGURATION
|
||||||
|
|
||||||
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
||||||
_voltage_superposition_client = new VoltageSuperPositionClient(object_id);
|
_voltage_superposition_client.UpdateEntryIds(object_id);
|
||||||
_client_manager->AddNewClient(_voltage_superposition_client);
|
_client_manager->AddNewClient(&_voltage_superposition_client);
|
||||||
|
|
||||||
_pulsing_rectangular_input_parser_client = new PulsingRectangularInputParserClient(object_id);
|
_pulsing_rectangular_input_parser_client.UpdateEntryIds(object_id);
|
||||||
_client_manager->AddNewClient(_pulsing_rectangular_input_parser_client);
|
_client_manager->AddNewClient(&_pulsing_rectangular_input_parser_client);
|
||||||
#endif //CONFIG_USE_PULSING_CONFIGURATION
|
#endif //CONFIG_USE_PULSING_CONFIGURATION
|
||||||
}
|
}
|
||||||
|
|
||||||
void VertiqConfigurationHandler::InitClientEntryWrappers()
|
void VertiqConfigurationHandler::InitClientEntryWrappers()
|
||||||
{
|
{
|
||||||
AddNewClientEntry<float, float>(param_find("VTQ_MAX_VELOCITY"), &(_prop_input_parser_client->velocity_max_));
|
AddNewClientEntry<float, float>(param_find("VTQ_MAX_VELOCITY"), &(_prop_input_parser_client.velocity_max_));
|
||||||
AddNewClientEntry<float, float>(param_find("VTQ_MAX_VOLTS"), &(_prop_input_parser_client->volts_max_));
|
AddNewClientEntry<float, float>(param_find("VTQ_MAX_VOLTS"), &(_prop_input_parser_client.volts_max_));
|
||||||
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_CONTROL_MODE"), &(_prop_input_parser_client->mode_));
|
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_CONTROL_MODE"), &(_prop_input_parser_client.mode_));
|
||||||
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_MOTOR_DIR"), &(_prop_input_parser_client->sign_));
|
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_MOTOR_DIR"), &(_prop_input_parser_client.sign_));
|
||||||
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_FC_DIR"), &(_prop_input_parser_client->flip_negative_));
|
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_FC_DIR"), &(_prop_input_parser_client.flip_negative_));
|
||||||
|
|
||||||
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
||||||
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_THROTTLE_CVI"), &(_ifci_client->throttle_cvi_));
|
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_THROTTLE_CVI"), &(_ifci_client.throttle_cvi_));
|
||||||
#endif //CONFIG_USE_IFCI_CONFIGURATION
|
#endif //CONFIG_USE_IFCI_CONFIGURATION
|
||||||
|
|
||||||
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
||||||
AddNewClientEntry<uint8_t, int32_t> (param_find("VTQ_PULSE_V_MODE"),
|
AddNewClientEntry<uint8_t, int32_t> (param_find("VTQ_PULSE_V_MODE"),
|
||||||
&(_pulsing_rectangular_input_parser_client->pulsing_voltage_mode_));
|
&(_pulsing_rectangular_input_parser_client.pulsing_voltage_mode_));
|
||||||
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_X_CVI"), &(_ifci_client->x_cvi_));
|
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_X_CVI"), &(_ifci_client.x_cvi_));
|
||||||
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_Y_CVI"), &(_ifci_client->y_cvi_));
|
AddNewClientEntry<uint8_t, int32_t>(param_find("VTQ_Y_CVI"), &(_ifci_client.y_cvi_));
|
||||||
AddNewClientEntry<float, float>(param_find("VTQ_ZERO_ANGLE"), &(_voltage_superposition_client->zero_angle_));
|
AddNewClientEntry<float, float>(param_find("VTQ_ZERO_ANGLE"), &(_voltage_superposition_client.zero_angle_));
|
||||||
AddNewClientEntry<float, float>(param_find("VTQ_VELO_CUTOFF"),
|
AddNewClientEntry<float, float>(param_find("VTQ_VELO_CUTOFF"),
|
||||||
&(_voltage_superposition_client->velocity_cutoff_));
|
&(_voltage_superposition_client.velocity_cutoff_));
|
||||||
AddNewClientEntry<float, float>(param_find("VTQ_TQUE_OFF_ANG"),
|
AddNewClientEntry<float, float>(param_find("VTQ_TQUE_OFF_ANG"),
|
||||||
&(_voltage_superposition_client->propeller_torque_offset_angle_));
|
&(_voltage_superposition_client.propeller_torque_offset_angle_));
|
||||||
AddNewClientEntry<float, float>(param_find("VTQ_PULSE_V_LIM"),
|
AddNewClientEntry<float, float>(param_find("VTQ_PULSE_V_LIM"),
|
||||||
&(_pulsing_rectangular_input_parser_client->pulsing_voltage_limit_));
|
&(_pulsing_rectangular_input_parser_client.pulsing_voltage_limit_));
|
||||||
#endif //CONFIG_USE_PULSING_CONFIGURATION
|
#endif //CONFIG_USE_PULSING_CONFIGURATION
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -91,15 +102,15 @@ void VertiqConfigurationHandler::UpdateClientsToNewObjId(uint8_t new_object_id)
|
|||||||
{
|
{
|
||||||
_object_id_now = new_object_id;
|
_object_id_now = new_object_id;
|
||||||
|
|
||||||
DestroyAndRecreateClient<EscPropellerInputParserClient>(_prop_input_parser_client, new_object_id);
|
_prop_input_parser_client.UpdateEntryIds(new_object_id);
|
||||||
|
|
||||||
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
||||||
DestroyAndRecreateClient<IQUartFlightControllerInterfaceClient>(_ifci_client, new_object_id);
|
_ifci_client.UpdateEntryIds(new_object_id);
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
||||||
DestroyAndRecreateClient<VoltageSuperPositionClient>(_voltage_superposition_client, new_object_id);
|
_voltage_superposition_client.UpdateEntryIds(new_object_id);
|
||||||
DestroyAndRecreateClient<PulsingRectangularInputParserClient>(_pulsing_rectangular_input_parser_client, new_object_id);
|
_pulsing_rectangular_input_parser_client.UpdateEntryIds(new_object_id);
|
||||||
#endif
|
#endif
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -114,8 +125,6 @@ void VertiqConfigurationHandler::UpdateIquartConfigParams()
|
|||||||
{
|
{
|
||||||
for (uint8_t i = 0; i < _added_configuration_entry_wrappers; i++) {
|
for (uint8_t i = 0; i < _added_configuration_entry_wrappers; i++) {
|
||||||
_configuration_entry_wrappers[i]->SendGet(_serial_interface);
|
_configuration_entry_wrappers[i]->SendGet(_serial_interface);
|
||||||
//Ensure that these get messages get out
|
|
||||||
_client_manager->HandleClientCommunication();
|
|
||||||
}
|
}
|
||||||
|
|
||||||
//Now go ahead and grab responses, and update everyone to be on the same page, but do it quickly.
|
//Now go ahead and grab responses, and update everyone to be on the same page, but do it quickly.
|
||||||
|
|||||||
@@ -89,7 +89,7 @@ public:
|
|||||||
*
|
*
|
||||||
* @param timeout The maximum amount of time we can keep trying to get responses
|
* @param timeout The maximum amount of time we can keep trying to get responses
|
||||||
*/
|
*/
|
||||||
void CoordinateIquartWithPx4Params(hrt_abstime timeout = 100_ms);
|
void CoordinateIquartWithPx4Params(hrt_abstime timeout = 10_ms);
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* @brief Gives access to the object ID currently being used
|
* @brief Gives access to the object ID currently being used
|
||||||
@@ -157,16 +157,16 @@ private:
|
|||||||
////////////////////////////////////////////////////////////////////////
|
////////////////////////////////////////////////////////////////////////
|
||||||
//Vertiq Client information
|
//Vertiq Client information
|
||||||
//Known Configuration Clients can be created as pointers to certain types of clients
|
//Known Configuration Clients can be created as pointers to certain types of clients
|
||||||
EscPropellerInputParserClient *_prop_input_parser_client;
|
EscPropellerInputParserClient _prop_input_parser_client;
|
||||||
|
|
||||||
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
#ifdef CONFIG_USE_IFCI_CONFIGURATION
|
||||||
//Make all of the clients that we need to talk to the IFCI config params
|
//Make all of the clients that we need to talk to the IFCI config params
|
||||||
IQUartFlightControllerInterfaceClient *_ifci_client;
|
IQUartFlightControllerInterfaceClient _ifci_client;
|
||||||
#endif //CONFIG_USE_IFCI_CONFIGURATION
|
#endif //CONFIG_USE_IFCI_CONFIGURATION
|
||||||
|
|
||||||
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
#ifdef CONFIG_USE_PULSING_CONFIGURATION
|
||||||
VoltageSuperPositionClient *_voltage_superposition_client;
|
VoltageSuperPositionClient _voltage_superposition_client;
|
||||||
PulsingRectangularInputParserClient *_pulsing_rectangular_input_parser_client;
|
PulsingRectangularInputParserClient _pulsing_rectangular_input_parser_client;
|
||||||
#endif //CONFIG_USE_PULSING_CONFIGURATION
|
#endif //CONFIG_USE_PULSING_CONFIGURATION
|
||||||
////////////////////////////////////////////////////////////////////////
|
////////////////////////////////////////////////////////////////////////
|
||||||
|
|
||||||
|
|||||||
@@ -153,7 +153,7 @@ void VertiqIo::Run()
|
|||||||
|
|
||||||
void VertiqIo::parameters_update()
|
void VertiqIo::parameters_update()
|
||||||
{
|
{
|
||||||
//If someone has changed any parameter in our module. Checked at 1Hz
|
//If someone has changed any parameter in our module. Checked periodically
|
||||||
if (_parameter_update_sub.updated()) {
|
if (_parameter_update_sub.updated()) {
|
||||||
//Grab the changed parameter with copy (which lowers the "changed" flag)
|
//Grab the changed parameter with copy (which lowers the "changed" flag)
|
||||||
parameter_update_s param_update;
|
parameter_update_s param_update;
|
||||||
|
|||||||
@@ -167,7 +167,7 @@ private:
|
|||||||
uORB::Publication<esc_status_s> _esc_status_pub{ORB_ID(esc_status)}; //We want to publish our ESC Status to anyone who will listen
|
uORB::Publication<esc_status_s> _esc_status_pub{ORB_ID(esc_status)}; //We want to publish our ESC Status to anyone who will listen
|
||||||
|
|
||||||
// Subscriptions
|
// Subscriptions
|
||||||
uORB::SubscriptionInterval _parameter_update_sub{ORB_ID(parameter_update), 1_s};
|
uORB::SubscriptionInterval _parameter_update_sub{ORB_ID(parameter_update), 10_ms};
|
||||||
|
|
||||||
//We need to know what's going on with the actuator test to make sure we handle it properly
|
//We need to know what's going on with the actuator test to make sure we handle it properly
|
||||||
uORB::Subscription _actuator_test_sub{ORB_ID(actuator_test)};
|
uORB::Subscription _actuator_test_sub{ORB_ID(actuator_test)};
|
||||||
|
|||||||
@@ -203,7 +203,7 @@ void VertiqSerialInterface::ProcessSerialRx(ClientAbstract **client_array, uint8
|
|||||||
ReOpenSerial();
|
ReOpenSerial();
|
||||||
|
|
||||||
//We have bytes
|
//We have bytes
|
||||||
if (CheckForRx()) {
|
while (CheckForRx()) {
|
||||||
uint8_t *data_ptr = ReadAndSetRxBytes();
|
uint8_t *data_ptr = ReadAndSetRxBytes();
|
||||||
|
|
||||||
//While we've got packets to look at, give the packet to each of the clients so that each
|
//While we've got packets to look at, give the packet to each of the clients so that each
|
||||||
|
|||||||
@@ -35,7 +35,8 @@
|
|||||||
|
|
||||||
VertiqTelemetryManager::VertiqTelemetryManager(VertiqClientManager *client_manager) :
|
VertiqTelemetryManager::VertiqTelemetryManager(VertiqClientManager *client_manager) :
|
||||||
_client_manager(client_manager),
|
_client_manager(client_manager),
|
||||||
_telem_state(UNPAUSED)
|
_telem_state(UNPAUSED),
|
||||||
|
_telem_interface(0)
|
||||||
{
|
{
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -45,8 +46,8 @@ void VertiqTelemetryManager::Init(uint64_t telem_bitmask, uint8_t module_id)
|
|||||||
_telem_bitmask = telem_bitmask;
|
_telem_bitmask = telem_bitmask;
|
||||||
FindTelemetryModuleIds();
|
FindTelemetryModuleIds();
|
||||||
|
|
||||||
_telem_interface = new IQUartFlightControllerInterfaceClient(module_id);
|
_telem_interface.UpdateEntryIds(module_id);
|
||||||
_client_manager->AddNewClient(_telem_interface);
|
_client_manager->AddNewClient(&_telem_interface);
|
||||||
}
|
}
|
||||||
|
|
||||||
void VertiqTelemetryManager::FindTelemetryModuleIds()
|
void VertiqTelemetryManager::FindTelemetryModuleIds()
|
||||||
@@ -106,9 +107,9 @@ uint16_t VertiqTelemetryManager::UpdateTelemetry()
|
|||||||
bool timed_out = (time_now - _time_of_last_telem_request) > _telem_timeout;
|
bool timed_out = (time_now - _time_of_last_telem_request) > _telem_timeout;
|
||||||
|
|
||||||
//We got a telemetry response
|
//We got a telemetry response
|
||||||
if (_telem_interface->telemetry_.IsFresh()) {
|
if (_telem_interface.telemetry_.IsFresh()) {
|
||||||
//grab the data
|
//grab the data
|
||||||
IFCITelemetryData telem_response = _telem_interface->telemetry_.get_reply();
|
IFCITelemetryData telem_response = _telem_interface.telemetry_.get_reply();
|
||||||
|
|
||||||
// also update our internal report for logging
|
// also update our internal report for logging
|
||||||
_esc_status.esc[_current_module_id_target_index].esc_address = _module_ids_in_use[_number_of_module_ids_for_telem];
|
_esc_status.esc[_current_module_id_target_index].esc_address = _module_ids_in_use[_number_of_module_ids_for_telem];
|
||||||
@@ -148,9 +149,8 @@ uint16_t VertiqTelemetryManager::UpdateTelemetry()
|
|||||||
uint16_t next_telem = FindNextMotorForTelemetry();
|
uint16_t next_telem = FindNextMotorForTelemetry();
|
||||||
|
|
||||||
if (next_telem != _impossible_module_id) {
|
if (next_telem != _impossible_module_id) {
|
||||||
//We need to update the module ID we're going to listen to. So, kill the old one, and make it anew.
|
//We need to update the module ID we're going to listen to
|
||||||
delete _telem_interface;
|
_telem_interface.UpdateEntryIds(next_telem);
|
||||||
_telem_interface = new IQUartFlightControllerInterfaceClient(next_telem);
|
|
||||||
}
|
}
|
||||||
|
|
||||||
//update the telem target
|
//update the telem target
|
||||||
|
|||||||
@@ -133,7 +133,7 @@ private:
|
|||||||
VertiqClientManager *_client_manager;
|
VertiqClientManager *_client_manager;
|
||||||
|
|
||||||
vertiq_telemetry_pause_states _telem_state; //Keep track of whether or not we've paused telemetry
|
vertiq_telemetry_pause_states _telem_state; //Keep track of whether or not we've paused telemetry
|
||||||
IQUartFlightControllerInterfaceClient *_telem_interface; //Used for reading responses from our telemetry targets
|
IQUartFlightControllerInterfaceClient _telem_interface; //Used for reading responses from our telemetry targets
|
||||||
esc_status_s _esc_status; //We want to publish our ESC Status to anyone who will listen
|
esc_status_s _esc_status; //We want to publish our ESC Status to anyone who will listen
|
||||||
static const uint8_t MAX_SUPPORTABLE_MODULE_IDS = 63; //[0, 62] //The max number of module IDs that we can support
|
static const uint8_t MAX_SUPPORTABLE_MODULE_IDS = 63; //[0, 62] //The max number of module IDs that we can support
|
||||||
static const uint8_t MAX_ESC_STATUS_ENTRIES =
|
static const uint8_t MAX_ESC_STATUS_ENTRIES =
|
||||||
|
|||||||
Reference in New Issue
Block a user