mirror of
https://github.com/PX4/PX4-Autopilot.git
synced 2026-06-02 03:49:12 +08:00
docs(update): Safetly settings for changes in ESC timeout handling
This commit is contained in:
+13
-11
@@ -314,22 +314,24 @@ The relevant parameters are shown below:
|
|||||||
|
|
||||||
### Motor Failure Trigger
|
### Motor Failure Trigger
|
||||||
|
|
||||||
The failure detector can be configured to detect a motor failure while armed (and trigger an associated action) in the following conditions:
|
The failure detector can be configured to detect a motor failure while armed (and trigger an associated action) if the ESC current falls outside expected bounds for more than [`MOTFAIL_TIME`](#MOTFAIL_TIME) seconds.
|
||||||
|
Motor failures are non-latching: if the failure condition clears, the failure is cleared.
|
||||||
|
|
||||||
- A 300 ms timeout occurs in telemetry from an ESC that was previously available.
|
The undercurrent and overcurrent conditions are defined by:
|
||||||
- The input current in the telemetry of an ESC which was previously positive gets too low for more than [`FD_ACT_MOT_TOUT`](FD_ACT_MOT_TOUT) ms.
|
|
||||||
The "too low" condition is defined by:
|
|
||||||
|
|
||||||
```text
|
```text
|
||||||
{esc current} < {parameter FD_ACT_MOT_C2T} * {motor command between 0 and 1}
|
undercurrent: {esc current} < {MOTFAIL_C2T} * {motor command [0,1]} - {MOTFAIL_LOW_OFF}
|
||||||
```
|
overcurrent: {esc current} > {MOTFAIL_C2T} * {motor command [0,1]} + {MOTFAIL_HIGH_OFF}
|
||||||
|
```
|
||||||
|
|
||||||
| Parameter | Description |
|
| Parameter | Description |
|
||||||
| -------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
| ----------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||||||
| <a id="FD_ACT_EN"></a>[FD_ACT_EN](../advanced_config/parameter_reference.md#FD_ACT_EN) | Enable/disable the motor failure trigger completely. |
|
| <a id="FD_ACT_EN"></a>[FD_ACT_EN](../advanced_config/parameter_reference.md#FD_ACT_EN) | Enable/disable the motor failure trigger completely. |
|
||||||
| <a id="FD_ACT_MOT_THR"></a>[FD_ACT_MOT_THR](../advanced_config/parameter_reference.md#FD_ACT_MOT_THR) | Minimum normalized [0,1] motor command below which motor under current is ignored. |
|
| <a id="MOTFAIL_THR"></a>[MOTFAIL_THR](../advanced_config/parameter_reference.md#MOTFAIL_THR) | Minimum normalised [0,1] motor command below which motor under current is ignored. |
|
||||||
| <a id="FD_ACT_MOT_C2T"></a>[FD_ACT_MOT_C2T](../advanced_config/parameter_reference.md#FD_ACT_MOT_C2T) | Scale between normalized [0,1] motor command and expected minimally reported current when the rotor is healthy. |
|
| <a id="MOTFAIL_C2T"></a>[MOTFAIL_C2T](../advanced_config/parameter_reference.md#MOTFAIL_C2T) | Scale between normalised [0,1] motor command and expected current when the rotor is healthy (current-to-thrust ratio, A). |
|
||||||
| <a id="FD_ACT_MOT_TOUT"></a>[FD_ACT_MOT_TOUT](../advanced_config/parameter_reference.md#FD_ACT_MOT_TOUT) | Time in milliseconds for which the under current detection condition needs to stay true. |
|
| <a id="MOTFAIL_LOW_OFF"></a>[MOTFAIL_LOW_OFF](../advanced_config/parameter_reference.md#MOTFAIL_LOW_OFF) | Undercurrent detection threshold offset (A). Subtracted from the expected current to form the lower bound. |
|
||||||
|
| <a id="MOTFAIL_HIGH_OFF"></a>[MOTFAIL_HIGH_OFF](../advanced_config/parameter_reference.md#MOTFAIL_HIGH_OFF) | Overcurrent detection threshold offset (A). Added to the expected current to form the upper bound. |
|
||||||
|
| <a id="MOTFAIL_TIME"></a>[MOTFAIL_TIME](../advanced_config/parameter_reference.md#MOTFAIL_TIME) | Hysteresis time (s) for which the current threshold must remain exceeded before a motor failure is triggered. |
|
||||||
| <a id="CA_FAILURE_MODE"></a>[CA_FAILURE_MODE](../advanced_config/parameter_reference.md#CA_FAILURE_MODE) | Configure to not only warn about a motor failure but remove the first motor that detects a failure from the allocation effectiveness which turns off the motor and tries to operate the vehicle without it until disarming the next time. |
|
| <a id="CA_FAILURE_MODE"></a>[CA_FAILURE_MODE](../advanced_config/parameter_reference.md#CA_FAILURE_MODE) | Configure to not only warn about a motor failure but remove the first motor that detects a failure from the allocation effectiveness which turns off the motor and tries to operate the vehicle without it until disarming the next time. |
|
||||||
|
|
||||||
### External Automatic Trigger System (ATS)
|
### External Automatic Trigger System (ATS)
|
||||||
|
|||||||
Reference in New Issue