mirror of
https://github.com/odriverobotics/ODrive.git
synced 2026-08-18 09:29:03 +08:00
rc2 changelog update
This commit is contained in:
+10
-2
@@ -2,7 +2,13 @@
|
||||
Please add a note of your changes below this heading if you make a Pull Request.
|
||||
|
||||
# Releases
|
||||
## [0.5.2] - 2021-05-05
|
||||
## [0.5.2] - 2021-05-15
|
||||
|
||||
### Fixed
|
||||
* spinout error is no longer sticky and doesn't trigger on static torque loads due to I^2*R electrical power
|
||||
* Step and direction mode resets position when entering closed loop just like `input_pos` does
|
||||
* CAN baud rate setting is now correctly handled
|
||||
|
||||
### Added
|
||||
* Added phase balance check to motor calibration and MOTOR_ERROR_UNBALANCED_PHASES to error enums
|
||||
* Added polarity and phase offset calibration for hall effect encoders
|
||||
@@ -11,10 +17,12 @@ Please add a note of your changes below this heading if you make a Pull Request.
|
||||
* Support for UART1 on GPIO3 and GPIO4. UART0 (on GPIO1/2) and UART1 can currently not be enabled at the same time.
|
||||
* Thermistors now have a 2nd order lowpass filter applied to reduce noise
|
||||
* 2-norm current clamping is used for AC induction motors
|
||||
* Added spinout detection to detect incorrect encoder offset and ENCODER_ERROR_INCORRECT_OFFSET to error enums.
|
||||
* Added spinout detection to detect incorrect encoder offset and CONTROLLER_ERROR_SPINOUT_DETECTED to error enums.
|
||||
* Added AARCH64 support to libfibre
|
||||
* Tuning input mode added to provide sinusoidal position, velocity, or torque stimulus. See INPUT_MODE_TUNING and the controller class for details.
|
||||
* Added torque mirroring to INPUT_MODE_MIRROR
|
||||
* `mechanical_power_bandwidth`, `electrical_power_bandwidth`, `spinout_electrical_power_threshold`, `spinout_mechanical_power_threshold` added to `controller.config` for spinout detection.
|
||||
* `mechanical_power` and `electrical_power` added to `controller`.
|
||||
|
||||
### Changed
|
||||
* Step/dir performance improved! Dual axis step rates up to 250kHz have been tested
|
||||
|
||||
Reference in New Issue