Clock_driver_support_at_tick() set the compare register ahead of the count register, so every period gained the latency of the interrupt. Measured over 100 ticks, a period of 100000 counts took 100277, which is 0.278 percent long. sptimecounter02 measured a job of a fixed number of clock ticks against the timecounter and failed with that drift. spintrcritical24 failed with it as well. The dummy timecounter hid the drift, because it took the uptime from the count of ticks rather than from a counter. Advance the compare register by the period. A handler which runs late computes a value which the counter already passed. The comparison then waits for the counter to run through its whole width. That is 27 seconds at the frequency of this BSP. Take the counter as the base of the next period in that case, as the or1k clock driver does. The period now measures 100000.08 counts. Update #5742. Assisted-by: Claude:claude-opus-5 claude-code Signed-off-by: Sebastian Huber <sebastian.huber@embedded-brains.de>