@@ -227,19 +227,19 @@ EtherCAT functionality (see chap.~\ref{chap:api}).
|
|
|
|
|
|
|
|
|
|
\end{itemize}
|
|
|
|
|
|
|
|
|
|
\item CANopen-over-EtherCAT (CoE)
|
|
|
|
|
\item CANopen over EtherCAT (CoE)
|
|
|
|
|
|
|
|
|
|
\begin{itemize}
|
|
|
|
|
|
|
|
|
|
\item Sdo upload, download and information service.
|
|
|
|
|
\item SDO upload, download and information service.
|
|
|
|
|
|
|
|
|
|
\item Slave configuration via Sdos.
|
|
|
|
|
\item Slave configuration via SDOs.
|
|
|
|
|
|
|
|
|
|
\item Sdo access from userspace and from the application.
|
|
|
|
|
\item SDO access from userspace and from the application.
|
|
|
|
|
|
|
|
|
|
\end{itemize}
|
|
|
|
|
|
|
|
|
|
\item Ethernet-over-EtherCAT (EoE)
|
|
|
|
|
\item Ethernet over EtherCAT (EoE)
|
|
|
|
|
|
|
|
|
|
\begin{itemize}
|
|
|
|
|
|
|
|
|
@@ -254,12 +254,12 @@ EtherCAT functionality (see chap.~\ref{chap:api}).
|
|
|
|
|
|
|
|
|
|
\begin{itemize}
|
|
|
|
|
|
|
|
|
|
\item Showing the current bus with slaves, Pdos and Sdos.
|
|
|
|
|
\item Showing the current bus with slaves, PDOs and SDOs.
|
|
|
|
|
\item Showing the bus configuration.
|
|
|
|
|
\item Showing domains and process data.
|
|
|
|
|
\item Setting the master's debug level.
|
|
|
|
|
\item Writing alias addresses.
|
|
|
|
|
\item Sdo uploading/downloading.
|
|
|
|
|
\item SDO uploading/downloading.
|
|
|
|
|
\item Reading/writing a slave's SII.
|
|
|
|
|
\item Setting slave states.
|
|
|
|
|
\item Generate slave description XML.
|
|
|
|
@@ -457,7 +457,7 @@ possible until then.
|
|
|
|
|
an Ethernet device, but is not requested by any application yet. The master
|
|
|
|
|
runs its state machine (see sec.~\ref{sec:fsm-master}), that automatically
|
|
|
|
|
scans the bus for slaves and executes pending operations from the userspace
|
|
|
|
|
interface (for example Sdo access). The command-line tool can be used to
|
|
|
|
|
interface (for example SDO access). The command-line tool can be used to
|
|
|
|
|
access the bus, but there is no process data exchange because of the missing
|
|
|
|
|
bus configuration.
|
|
|
|
|
|
|
|
|
@@ -478,12 +478,12 @@ process data.
|
|
|
|
|
\index{Process data}
|
|
|
|
|
|
|
|
|
|
Slaves offer their inputs and outputs by presenting the master so-called
|
|
|
|
|
``Process Data Objects'' (Pdos\index{Pdo}). The available Pdos can be either
|
|
|
|
|
``Process Data Objects'' (PDOs\index{PDO}). The available PDOs can be either
|
|
|
|
|
determined by reading out the slave's TXPDO and RXPDO SII categories from the
|
|
|
|
|
E$^2$PROM (in case of fixed Pdos) or by reading out the appropriate CoE
|
|
|
|
|
E$^2$PROM (in case of fixed PDOs) or by reading out the appropriate CoE
|
|
|
|
|
objects (see sec.~\ref{sec:coe}), if available. The application can register
|
|
|
|
|
the Pdos' entries for exchange during cyclic operation. The sum of all
|
|
|
|
|
registered Pdo entries defines the ``process data image'', which is exchanged
|
|
|
|
|
the PDOs' entries for exchange during cyclic operation. The sum of all
|
|
|
|
|
registered PDO entries defines the ``process data image'', which is exchanged
|
|
|
|
|
via datagrams with ``logical'' memory access (like LWR, LRD or LRW) introduced
|
|
|
|
|
in~\cite[sec.~5.4]{dlspec}.
|
|
|
|
|
|
|
|
|
@@ -491,8 +491,8 @@ in~\cite[sec.~5.4]{dlspec}.
|
|
|
|
|
\index{Domain}
|
|
|
|
|
|
|
|
|
|
The process data image can be easily managed by creating so-called
|
|
|
|
|
``domains'', which allow grouped Pdo exchange. They also take care of managing
|
|
|
|
|
the datagram structures needed to exchange the Pdos. Domains are mandatory for
|
|
|
|
|
``domains'', which allow grouped PDO exchange. They also take care of managing
|
|
|
|
|
the datagram structures needed to exchange the PDOs. Domains are mandatory for
|
|
|
|
|
process data exchange, so there has to be at least one. They were introduced
|
|
|
|
|
for the following reasons:
|
|
|
|
|
|
|
|
|
@@ -506,10 +506,10 @@ image exceeds this limit, multiple frames have to be sent, and the image has
|
|
|
|
|
to be partitioned for the use of multiple datagrams. A domain manages this
|
|
|
|
|
automatically.
|
|
|
|
|
|
|
|
|
|
\item Not every Pdo has to be exchanged with the same frequency: The values of
|
|
|
|
|
Pdos can vary slowly over time (for example temperature values), so exchanging
|
|
|
|
|
\item Not every PDO has to be exchanged with the same frequency: The values of
|
|
|
|
|
PDOs can vary slowly over time (for example temperature values), so exchanging
|
|
|
|
|
them with a high frequency would just waste bus bandwidth. For this reason,
|
|
|
|
|
multiple domains can be created, to group different Pdos and so allow separate
|
|
|
|
|
multiple domains can be created, to group different PDOs and so allow separate
|
|
|
|
|
exchange.
|
|
|
|
|
|
|
|
|
|
\end{itemize}
|
|
|
|
@@ -521,21 +521,21 @@ limited by the slaves.
|
|
|
|
|
\paragraph{FMMU Configuration}
|
|
|
|
|
\index{FMMU!Configuration}
|
|
|
|
|
|
|
|
|
|
An application can register Pdo entries for exchange. Every Pdo entry and its
|
|
|
|
|
parent Pdo is part of a memory area in the slave's physical memory, that is
|
|
|
|
|
An application can register PDO entries for exchange. Every PDO entry and its
|
|
|
|
|
parent PDO is part of a memory area in the slave's physical memory, that is
|
|
|
|
|
protected by a sync manager \cite[sec.~6.7]{dlspec} for synchronized access.
|
|
|
|
|
In order to make a sync manager react on a datagram accessing its memory, it
|
|
|
|
|
is necessary to access the last byte covered by the sync manager. Otherwise
|
|
|
|
|
the sync manager will not react on the datagram and no data will be exchanged.
|
|
|
|
|
That is why the whole synchronized memory area has to be included into the
|
|
|
|
|
process data image: For example, if a certain Pdo entry of a slave is
|
|
|
|
|
process data image: For example, if a certain PDO entry of a slave is
|
|
|
|
|
registered for exchange with a certain domain, one FMMU will be configured to
|
|
|
|
|
map the complete sync-manager-protected memory, the Pdo entry resides in. If a
|
|
|
|
|
second Pdo entry of the same slave is registered for process data exchange
|
|
|
|
|
map the complete sync-manager-protected memory, the PDO entry resides in. If a
|
|
|
|
|
second PDO entry of the same slave is registered for process data exchange
|
|
|
|
|
within the same domain, and it resides in the same sync-manager-protected
|
|
|
|
|
memory as the first one, the FMMU configuration is not altered, because the
|
|
|
|
|
desired memory is already part of the domain's process data image. If the
|
|
|
|
|
second Pdo entry would belong to another sync-manager-protected area, this
|
|
|
|
|
second PDO entry would belong to another sync-manager-protected area, this
|
|
|
|
|
complete area would also be included into the domains process data image.
|
|
|
|
|
|
|
|
|
|
Figure~\ref{fig:fmmus} gives an overview, how FMMUs are configured to map
|
|
|
|
@@ -559,11 +559,11 @@ physical memory to logical process data images.
|
|
|
|
|
% Interface version
|
|
|
|
|
% Master Requesting and Releasing
|
|
|
|
|
% Master Locking
|
|
|
|
|
% Configuring Pdo assignment and mapping
|
|
|
|
|
% Configuring PDO assignment and mapping
|
|
|
|
|
% Domains (memory)
|
|
|
|
|
% Pdo entry registration
|
|
|
|
|
% Sdo configuration
|
|
|
|
|
% Sdo access
|
|
|
|
|
% PDO entry registration
|
|
|
|
|
% SDO configuration
|
|
|
|
|
% SDO access
|
|
|
|
|
|
|
|
|
|
The application interface provides functions and data structures for
|
|
|
|
|
applications to access an EtherCAT master. The complete documentation of the
|
|
|
|
@@ -580,7 +580,7 @@ Every application should use the master in two steps:
|
|
|
|
|
\begin{description}
|
|
|
|
|
|
|
|
|
|
\item[Configuration] The master is requested and the configuration is applied.
|
|
|
|
|
For example, domains are created, slaves are configured and Pdo entries are
|
|
|
|
|
For example, domains are created, slaves are configured and PDO entries are
|
|
|
|
|
registered (see sec.~\ref{sec:masterconfig}).
|
|
|
|
|
|
|
|
|
|
\item[Operation] Cyclic code is run and process data are exchanged (see
|
|
|
|
@@ -1470,7 +1470,7 @@ monitored. If a slave is not in the state it supposed to be, the slave is
|
|
|
|
|
|
|
|
|
|
\item[Request handling] Requests (either originating from the application or
|
|
|
|
|
from external sources) are handled. A request is a job that the master shall
|
|
|
|
|
process asynchronously, for example an SII access, Sdo access, or similar.
|
|
|
|
|
process asynchronously, for example an SII access, SDO access, or similar.
|
|
|
|
|
|
|
|
|
|
\end{description}
|
|
|
|
|
|
|
|
|
@@ -1512,10 +1512,10 @@ image memory.
|
|
|
|
|
|
|
|
|
|
\item[PREOP] If the slave supports CoE, it is set to PREOP state using the
|
|
|
|
|
State change FSM (see sec.~\ref{sec:fsm-change}) to enable mailbox
|
|
|
|
|
communication and read the Pdo configuration via CoE.
|
|
|
|
|
communication and read the PDO configuration via CoE.
|
|
|
|
|
|
|
|
|
|
\item[Pdos] The Pdos are read via CoE (if supported) using the Pdo Reading FSM
|
|
|
|
|
(see sec.~\ref{sec:fsm-pdo}). If this is successful, the Pdo information from
|
|
|
|
|
\item[PDOs] The PDOs are read via CoE (if supported) using the PDO Reading FSM
|
|
|
|
|
(see sec.~\ref{sec:fsm-pdo}). If this is successful, the PDO information from
|
|
|
|
|
the SII (if any) is overwritten.
|
|
|
|
|
|
|
|
|
|
\end{description}
|
|
|
|
@@ -1554,18 +1554,18 @@ is skipped.
|
|
|
|
|
\item[PREOP] The state change FSM is used to bring the slave to PREOP state.
|
|
|
|
|
If this is the requested state, the state machine is finished.
|
|
|
|
|
|
|
|
|
|
\item[Sdo Configuration] If there is a slave configuration attached (see
|
|
|
|
|
sec.~\ref{sec:masterconfig}), and there are any Sdo configurations are
|
|
|
|
|
\item[SDO Configuration] If there is a slave configuration attached (see
|
|
|
|
|
sec.~\ref{sec:masterconfig}), and there are any SDO configurations are
|
|
|
|
|
provided by the application, these are sent to the slave.
|
|
|
|
|
|
|
|
|
|
\item[Pdo Configuration] The Pdo configuration state machine is executed to
|
|
|
|
|
apply all necessary Pdo configurations.
|
|
|
|
|
\item[PDO Configuration] The PDO configuration state machine is executed to
|
|
|
|
|
apply all necessary PDO configurations.
|
|
|
|
|
|
|
|
|
|
\item[Pdo Sync Manager Configuration] If any Pdo sync managers exist, they are
|
|
|
|
|
\item[PDO Sync Manager Configuration] If any PDO sync managers exist, they are
|
|
|
|
|
configured.
|
|
|
|
|
|
|
|
|
|
\item[FMMU Configuration] If there are FMMUs configurations supplied by the
|
|
|
|
|
application (i.\,e.\ if the application registered Pdo entries), they are
|
|
|
|
|
application (i.\,e.\ if the application registered PDO entries), they are
|
|
|
|
|
applied.
|
|
|
|
|
|
|
|
|
|
\item[SAFEOP] The state change FSM is used to bring the slave to SAFEOP state.
|
|
|
|
@@ -1677,60 +1677,60 @@ this state to avoid that another write operation is issued too early.
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\section{The Pdo State Machines}
|
|
|
|
|
\section{The PDO State Machines}
|
|
|
|
|
\label{sec:fsm-pdo}
|
|
|
|
|
\index{FSM!Pdo}
|
|
|
|
|
\index{FSM!PDO}
|
|
|
|
|
|
|
|
|
|
The Pdo state machines are a set of state machines that read or write the Pdo
|
|
|
|
|
assignment and the Pdo mapping via the ``CoE Communication Area'' described in
|
|
|
|
|
\cite[sec. 5.6.7.4]{alspec}. For the object access, the CANopen-over-EtherCAT
|
|
|
|
|
The PDO state machines are a set of state machines that read or write the PDO
|
|
|
|
|
assignment and the PDO mapping via the ``CoE Communication Area'' described in
|
|
|
|
|
\cite[sec. 5.6.7.4]{alspec}. For the object access, the CANopen over EtherCAT
|
|
|
|
|
access primitives are used (see sec.~\ref{sec:coe}), so the slave must support
|
|
|
|
|
the CoE mailbox protocol.
|
|
|
|
|
|
|
|
|
|
\paragraph{Pdo Reading FSM} This state machine (fig.~\ref{fig:fsm-pdo-read})
|
|
|
|
|
has the purpose to read the complete Pdo configuration of a slave. It reads
|
|
|
|
|
the Pdo assignment for each Sync Manager and uses the Pdo Entry Reading FSM
|
|
|
|
|
(fig.~\ref{fig:fsm-pdo-entry-read}) to read the mapping for each assigned Pdo.
|
|
|
|
|
\paragraph{PDO Reading FSM} This state machine (fig.~\ref{fig:fsm-pdo-read})
|
|
|
|
|
has the purpose to read the complete PDO configuration of a slave. It reads
|
|
|
|
|
the PDO assignment for each Sync Manager and uses the PDO Entry Reading FSM
|
|
|
|
|
(fig.~\ref{fig:fsm-pdo-entry-read}) to read the mapping for each assigned PDO.
|
|
|
|
|
|
|
|
|
|
\begin{figure}[htbp]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=.4\textwidth]{graphs/fsm_pdo_read}
|
|
|
|
|
\caption{Transition Diagram of the Pdo Reading State Machine}
|
|
|
|
|
\caption{Transition Diagram of the PDO Reading State Machine}
|
|
|
|
|
\label{fig:fsm-pdo-read}
|
|
|
|
|
\end{figure}
|
|
|
|
|
|
|
|
|
|
Basically it reads the every Sync manager's Pdo assignment Sdo's
|
|
|
|
|
Basically it reads the every Sync manager's PDO assignment SDO's
|
|
|
|
|
(\lstinline+0x1C1x+) number of elements to determine the number of assigned
|
|
|
|
|
Pdos for this sync manager and then reads out the subindices of the Sdo to get
|
|
|
|
|
the assigned Pdo's indices. When a Pdo index is read, the Pdo Entry Reading
|
|
|
|
|
FSM is executed to read the Pdo's mapped Pdo entries.
|
|
|
|
|
PDOs for this sync manager and then reads out the subindices of the SDO to get
|
|
|
|
|
the assigned PDO's indices. When a PDO index is read, the PDO Entry Reading
|
|
|
|
|
FSM is executed to read the PDO's mapped PDO entries.
|
|
|
|
|
|
|
|
|
|
\paragraph{Pdo Entry Reading FSM} This state machine
|
|
|
|
|
(fig.~\ref{fig:fsm-pdo-entry-read}) reads the Pdo mapping (the Pdo entries) of
|
|
|
|
|
a Pdo. It reads the respective mapping Sdo (\lstinline+0x1600+ --
|
|
|
|
|
\paragraph{PDO Entry Reading FSM} This state machine
|
|
|
|
|
(fig.~\ref{fig:fsm-pdo-entry-read}) reads the PDO mapping (the PDO entries) of
|
|
|
|
|
a PDO. It reads the respective mapping SDO (\lstinline+0x1600+ --
|
|
|
|
|
\lstinline+0x17ff+, or \lstinline+0x1a00+ -- \lstinline+0x1bff+) for the given
|
|
|
|
|
Pdo by reading first the subindex zero (number of elements) to determine the
|
|
|
|
|
number of mapped Pdo entries. After that, each subindex is read to get the
|
|
|
|
|
mapped Pdo entry index, subindex and bit size.
|
|
|
|
|
PDO by reading first the subindex zero (number of elements) to determine the
|
|
|
|
|
number of mapped PDO entries. After that, each subindex is read to get the
|
|
|
|
|
mapped PDO entry index, subindex and bit size.
|
|
|
|
|
|
|
|
|
|
\begin{figure}[htbp]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=.4\textwidth]{graphs/fsm_pdo_entry_read}
|
|
|
|
|
\caption{Transition Diagram of the Pdo Entry Reading State Machine}
|
|
|
|
|
\caption{Transition Diagram of the PDO Entry Reading State Machine}
|
|
|
|
|
\label{fig:fsm-pdo-entry-read}
|
|
|
|
|
\end{figure}
|
|
|
|
|
|
|
|
|
|
\begin{figure}[htbp]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=.9\textwidth]{graphs/fsm_pdo_conf}
|
|
|
|
|
\caption{Transition Diagram of the Pdo Configuration State Machine}
|
|
|
|
|
\caption{Transition Diagram of the PDO Configuration State Machine}
|
|
|
|
|
\label{fig:fsm-pdo-conf}
|
|
|
|
|
\end{figure}
|
|
|
|
|
|
|
|
|
|
\begin{figure}[htbp]
|
|
|
|
|
\centering
|
|
|
|
|
\includegraphics[width=.4\textwidth]{graphs/fsm_pdo_entry_conf}
|
|
|
|
|
\caption{Transition Diagram of the Pdo Entry Configuration State Machine}
|
|
|
|
|
\caption{Transition Diagram of the PDO Entry Configuration State Machine}
|
|
|
|
|
\label{fig:fsm-pdo-entry-conf}
|
|
|
|
|
\end{figure}
|
|
|
|
|
|
|
|
|
@@ -1744,12 +1744,12 @@ protocols. See the below section for details.
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\section{Ethernet-over-EtherCAT (EoE)}
|
|
|
|
|
\section{Ethernet over EtherCAT (EoE)}
|
|
|
|
|
\label{sec:eoe}
|
|
|
|
|
\index{EoE}
|
|
|
|
|
|
|
|
|
|
The EtherCAT master implements the
|
|
|
|
|
Ethernet-over-EtherCAT\nomenclature{EoE}{Ethernet-over-EtherCAT, Mailbox
|
|
|
|
|
Ethernet over EtherCAT\nomenclature{EoE}{Ethernet over EtherCAT, Mailbox
|
|
|
|
|
Protocol} mailbox protocol~\cite[sec.~5.7]{alspec} to enable the tunneling of
|
|
|
|
|
Ethernet frames to special slaves, that can either have physical Ethernet
|
|
|
|
|
ports to forward the frames to, or have an own IP stack to receive the frames.
|
|
|
|
@@ -1903,11 +1903,11 @@ application-layer state is automatically set to OP.
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\section{CANopen-over-EtherCAT (CoE)}
|
|
|
|
|
\section{CANopen over EtherCAT (CoE)}
|
|
|
|
|
\label{sec:coe}
|
|
|
|
|
\index{CoE}
|
|
|
|
|
|
|
|
|
|
The CANopen-over-EtherCAT\nomenclature{CoE}{CANopen-over-EtherCAT, Mailbox
|
|
|
|
|
The CANopen over EtherCAT\nomenclature{CoE}{CANopen over EtherCAT, Mailbox
|
|
|
|
|
Protocol} protocol~\cite[sec.~5.6]{alspec} is used to configure slaves and
|
|
|
|
|
exchange data objects on application level.
|
|
|
|
|
|
|
|
|
@@ -1916,23 +1916,23 @@ exchange data objects on application level.
|
|
|
|
|
% Download / Upload
|
|
|
|
|
% Expedited / Normal
|
|
|
|
|
% Segmenting
|
|
|
|
|
% Sdo Info Services
|
|
|
|
|
% SDO Info Services
|
|
|
|
|
%
|
|
|
|
|
|
|
|
|
|
\ldots
|
|
|
|
|
|
|
|
|
|
\paragraph{Sdo Download State Machine}
|
|
|
|
|
\paragraph{SDO Download State Machine}
|
|
|
|
|
|
|
|
|
|
The best time to apply Sdo configurations is during the slave's PREOP state,
|
|
|
|
|
The best time to apply SDO configurations is during the slave's PREOP state,
|
|
|
|
|
because mailbox communication is already possible and slave's application will
|
|
|
|
|
start with updating input data in the succeeding SAFEOP state. Therefore the
|
|
|
|
|
Sdo configuration has to be part of the slave configuration state machine (see
|
|
|
|
|
sec.~\ref{sec:fsm-conf}): It is implemented via an Sdo download state machine,
|
|
|
|
|
SDO configuration has to be part of the slave configuration state machine (see
|
|
|
|
|
sec.~\ref{sec:fsm-conf}): It is implemented via an SDO download state machine,
|
|
|
|
|
that is executed just before entering the slave's SAFEOP state. In this way,
|
|
|
|
|
it is guaranteed that the Sdo configurations are applied each time, the slave
|
|
|
|
|
it is guaranteed that the SDO configurations are applied each time, the slave
|
|
|
|
|
is reconfigured.
|
|
|
|
|
|
|
|
|
|
The transition diagram of the Sdo Download state machine can be seen
|
|
|
|
|
The transition diagram of the SDO Download state machine can be seen
|
|
|
|
|
in figure~\ref{fig:fsm-coedown}.
|
|
|
|
|
|
|
|
|
|
\begin{figure}[htbp]
|
|
|
|
@@ -1946,7 +1946,7 @@ in figure~\ref{fig:fsm-coedown}.
|
|
|
|
|
|
|
|
|
|
\begin{description}
|
|
|
|
|
\item[START] The beginning state of the CoE download state
|
|
|
|
|
machine. The ``Sdo Download Normal Request'' mailbox command is
|
|
|
|
|
machine. The ``SDO Download Normal Request'' mailbox command is
|
|
|
|
|
sent. $\rightarrow$~REQUEST
|
|
|
|
|
|
|
|
|
|
\item[REQUEST] It is checked, if the CoE download request has been
|
|
|
|
@@ -1955,7 +1955,7 @@ in figure~\ref{fig:fsm-coedown}.
|
|
|
|
|
|
|
|
|
|
\item[CHECK] If no mailbox data is available, the timer is checked.
|
|
|
|
|
\begin{itemize}
|
|
|
|
|
\item If it timed out, the Sdo download is aborted.
|
|
|
|
|
\item If it timed out, the SDO download is aborted.
|
|
|
|
|
$\rightarrow$~ERROR
|
|
|
|
|
\item Otherwise, the mailbox is queried again.
|
|
|
|
|
$\rightarrow$~CHECK
|
|
|
|
@@ -1965,22 +1965,22 @@ in figure~\ref{fig:fsm-coedown}.
|
|
|
|
|
$\rightarrow$~RESPONSE
|
|
|
|
|
|
|
|
|
|
\item[RESPONSE] If the mailbox response could not be fetched, the data
|
|
|
|
|
is invalid, the wrong protocol was received, or a ``Abort Sdo
|
|
|
|
|
Transfer Request'' was received, the Sdo download is aborted.
|
|
|
|
|
is invalid, the wrong protocol was received, or a ``Abort SDO
|
|
|
|
|
Transfer Request'' was received, the SDO download is aborted.
|
|
|
|
|
$\rightarrow$~ERROR
|
|
|
|
|
|
|
|
|
|
If a ``Sdo Download Normal Response'' acknowledgement was received,
|
|
|
|
|
the Sdo download was successful. $\rightarrow$~END
|
|
|
|
|
If a ``SDO Download Normal Response'' acknowledgement was received,
|
|
|
|
|
the SDO download was successful. $\rightarrow$~END
|
|
|
|
|
|
|
|
|
|
\item[END] The Sdo download was successful.
|
|
|
|
|
\item[END] The SDO download was successful.
|
|
|
|
|
|
|
|
|
|
\item[ERROR] The Sdo download was aborted due to an error.
|
|
|
|
|
\item[ERROR] The SDO download was aborted due to an error.
|
|
|
|
|
|
|
|
|
|
\end{description}
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\section{Vendor-specific-over-EtherCAT (VoE)}
|
|
|
|
|
\section{Vendor specific over EtherCAT (VoE)}
|
|
|
|
|
\label{sec:voe}
|
|
|
|
|
\index{VoE}
|
|
|
|
|
|
|
|
|
@@ -2087,19 +2087,19 @@ sec.~\ref{sec:autonode} for how to install and configure it.
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\subsection{Sync Managers, Pdos and Pdo Entries}
|
|
|
|
|
\subsection{Sync Managers, PDOs and PDO Entries}
|
|
|
|
|
|
|
|
|
|
\lstinputlisting[basicstyle=\ttfamily\footnotesize]{external/ethercat_pdos}
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\subsection{Sdo Dictionary}
|
|
|
|
|
\subsection{SDO Dictionary}
|
|
|
|
|
|
|
|
|
|
\lstinputlisting[basicstyle=\ttfamily\footnotesize]{external/ethercat_sdos}
|
|
|
|
|
|
|
|
|
|
%------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
\subsection{Sdo Access}
|
|
|
|
|
\subsection{SDO Access}
|
|
|
|
|
|
|
|
|
|
\lstinputlisting[basicstyle=\ttfamily\footnotesize]{external/ethercat_download}
|
|
|
|
|
|
|
|
|
|