mirror of
https://github.com/thiagoralves/OpenPLC_v3.git
synced 2026-08-19 03:52:52 +08:00
43 lines
1.4 KiB
Plaintext
43 lines
1.4 KiB
Plaintext
License
|
|
-------
|
|
Test programs of this directory are provided under BSD license (see associated
|
|
LICENSE file).
|
|
|
|
Compilation
|
|
-----------
|
|
After installation, you can use pkg-config to compile these tests.
|
|
For example, to compile random-test-server run:
|
|
|
|
gcc random-test-server.c -o random-test-server `pkg-config --libs --cflags libmodbus`
|
|
|
|
random-test-server
|
|
-----------------
|
|
It's necessary to launch this server before run random-test-client. By
|
|
default, it receives and responses to Modbus query on the localhost
|
|
and port 1502.
|
|
|
|
random-test-client
|
|
------------------
|
|
This programm sends many different queries to a large range of
|
|
addresses and values to test the communication between the client and
|
|
the server.
|
|
|
|
unit-test-server
|
|
unit-test-client
|
|
----------------
|
|
By default, this program sends some queries with the values defined in
|
|
unit-test.h and checks the responses. These programs are useful to
|
|
test the protocol implementation.
|
|
|
|
bandwidth-server-one
|
|
bandwidth-server-many-up
|
|
bandwidth-client
|
|
-----------------------
|
|
It returns some very useful informations about the performance of
|
|
transfert rate between the server and the client.
|
|
|
|
- bandwidth-server-one: it can handles only one connection with a client.
|
|
- bandwidth-server-many-up: it opens a connection each time a new client asks
|
|
for, but the number of connection is limited. The same server process handles
|
|
all the connections.
|