mirror of
https://github.com/thiagoralves/OpenPLC_v3.git
synced 2026-08-18 19:48:42 +08:00
481 lines
19 KiB
Plaintext
481 lines
19 KiB
Plaintext
libmodbus 3.1.3 (XXXX-XX-XX)
|
|
============================
|
|
|
|
- Introduce offsets in modbus mappings.
|
|
- Add some more macros for data manipulation.
|
|
- Change order of few functions in modbus RTU code.
|
|
- Add entries for modbus_rtu_[get|set]_delay in documentation index.
|
|
- Implemented runtime configurable RTS delay by Jimmy Bergström.
|
|
- Add an entry in libmodbus index page for modbus_rtu_set_custom_rts.
|
|
- Add support for user defined RTS toggle function by Jimmy
|
|
Bergström.
|
|
- Added ILLEGAL_DATA_ADDRESS tests for modbus_write_register[|s].
|
|
Thanks to Andrey Skvortsov.
|
|
- Update documentation of modbus_rtu_set_rts
|
|
- fix rts signal switch time by Hiromasa Ihara.
|
|
- Improve new_rtu and set_slave documentation (related to #276).
|
|
- Fix late check of ctx in modbus_reply[|_exception] (closes #269).
|
|
- Wait the server for 1 second before running tests (help Travis).
|
|
- A libmodbus context isn't thread safe and won't be (closes #246).
|
|
- Fix buffer overflow in modbus_mask_write_register (#265).
|
|
- Minor adjustments to README about AsciiDoc.
|
|
- Export MODBUS_MAX_ADU_LENGTH and documentation (ref #241).
|
|
- Explicit check against Modbus broadcast address.
|
|
- Do not reply on broadcast requests (fixes #153). Thanks to Michael.
|
|
- Add Travis support.
|
|
- Run unit tests with standard: make check (closes #205, closes #238).
|
|
This patch has been developed by Andrey Skvortsov, Michael Heimpold
|
|
and Stéphane Raimbault.
|
|
- modbus_send_raw_request: limit request length (fixes #207).
|
|
Thanks to Hanno Neuer for spotting this security flaw.
|
|
- Add new contributors to AUTHORS
|
|
- Introduce SPDX license identifiers. Thanks to Michael Heimpold.
|
|
|
|
libmodbus 3.1.2 (2015-02-13)
|
|
============================
|
|
|
|
If you still want to listen any addresses in your TCP IPv4 server, you must now
|
|
set the IP address to NULL in modbus_new_tcp before listening. Now,
|
|
modbus_tcp_listen only listen the IP address set in the Modbus context (see
|
|
documentation).
|
|
|
|
This release introduces API changes on modbus_get_byte_timeout,
|
|
modbus_get_response_timeout, modbus_set_byte_timeout,
|
|
modbus_set_response_timeout to ease writing of language bindings.
|
|
|
|
- Rewrite documentation building system
|
|
- Fix timeouts in unit tests
|
|
- Don't flush on illegal address errors in single write functions
|
|
- Fix compilation on compilers not supporting c99 mode.
|
|
Thanks to Michael Heimpold.
|
|
- Update license for the tests in Debian packaging (#221)
|
|
- Move check of device earlier to avoid a free call
|
|
- Unit test for baud rate check and error message.
|
|
- Fix crash modbus_new_rtu when baud is 0.
|
|
Thank you to Daniel Schürmann.
|
|
- Removed function prototype without implementation
|
|
Thank you Andrej Skvortzov.
|
|
- Switch test programs to a BSD license
|
|
- Fix remote buffer overflow vulnerability on write requests
|
|
- Avoid twice connect() in source code (closes #194)
|
|
- Fix compilation with MinGW (GCC 4.8.1) under Win7 (closes #163)
|
|
Thank you MarjanTomas and SwissKnife.
|
|
- Fix TCP IPv4 modbus_connect() on win32 (closes #100 and #165)
|
|
Thank you Petr Gladkiy and Marjan Tomas.
|
|
- Fix 24a05ebd3c0 - win32: init of modbus_tcp_pi_listen (#187)
|
|
- INADDR_* macros are defined in host byte order
|
|
- Filter of IP addresses in IPv4 server (closes #190)
|
|
- Allow to listen any hosts in IPv6 (closes #32)
|
|
- Define and public export of MODBUS_MAX_PDU_LENGTH (closes #167)
|
|
- Truncate data from response in report_slave_id to new max arg (closes #167)
|
|
- Fix response timeout modification on connect (closes #80)
|
|
- New API to set/get response and byte timeouts.
|
|
New unit tests and updated documentation.
|
|
- Export Modbus function codes supported by libmodbus
|
|
- Fix bandwidth-server-one (closes #152)
|
|
- Check debug flag in RTU code
|
|
- Remove warnings caused by shadowed 'index' variable.
|
|
Thanks to Åke Forslund.
|
|
- Use accept4 in TCP PI if available
|
|
- Add documentation for tcp[_pi]_accept (closes #31)
|
|
- Fix mistake in modbus_tcp_listen documentation
|
|
- Add documentation for modbus_tcp_pi_listen
|
|
- Fix for MinGW and Windows (#144, #169, #175, #180, #181, #187)
|
|
Thanks to Marjan Tomas.
|
|
- Many other fixes (#134, #157, #158, #183, #184) and improvements.
|
|
|
|
libmodbus 3.1.1 (2013-10-06)
|
|
============================
|
|
|
|
More robust to exploits, more compliant and better handling of connect/close
|
|
sequences. Windows support still broken.
|
|
|
|
- New unit tests
|
|
- Fix remote buffer overflow vulnerability (closes #25, #105)
|
|
- Explain how to define response timeouts when many RTU slaves
|
|
- Fix receiving of incorrect queries in write_single and mask_write_register
|
|
Thanks to James Nutaro.
|
|
- Check return value of autoreconf.
|
|
Thanks to Lauri Nurmi
|
|
- Constant for broacast and test ordering
|
|
- Fix the fix of device string check
|
|
- Various changes to try to improve *broken* Windows support
|
|
- Try to fix MinGW compilation
|
|
- Portable use of bswap_32
|
|
- Improve support of MacOS X
|
|
- Fix socket value on init/close
|
|
- Returns -1 on invalid mode in modbus_rtu_set_rts
|
|
- Protect all public functions against invalid context
|
|
- Sleep for delay of response timeout before reconnect (closes #77).
|
|
Thanks to Karl Palsson.
|
|
- Baud rate until 4,000,000 (POSIX), 1,000,000 (Windows) (closes #93)
|
|
- New modbus_get|set_float_dcba to get|set float in inversed byte order
|
|
- Remove unsupported -Wtype-limits for GCC < 4.3.5 (closes #109)
|
|
- Enable out-of-source build. Thanks to Yegor Yefremov.
|
|
- Fix alignment problem on ARMv5 platform
|
|
- Improvement to Debian package. Thanks to Alexander Klauer.
|
|
- Improve support of VS 2005. Thanks to Petr Gladkiy.
|
|
- Add documentation for modbus_mask_write_register (closes #91).
|
|
Thanks to Martijn de Gouw.
|
|
- Avoid C99 declaration in win32 section code (closes #92).
|
|
Thanks to oldfaber and endrelovas.
|
|
- Add a windows scripting host configure file.
|
|
Thanks to oldfaber and Stéphane Raimbault.
|
|
- Fix typo in modbus_strerror documentation. Thanks to Mirko Rajkovaca.
|
|
- Rename reserved C++ keywords of modbus_mask_write_register.
|
|
Thanks Tobias Doerffel.
|
|
- Another quick workaround for deficient OS (closes #63)
|
|
- Add support for Mask Write Register
|
|
- Fix missing close on socket in random-test-server.
|
|
Thanks to Damian Zieliński.
|
|
- Use nonblocking sockets on Win32 and OS X/iOS too.
|
|
Thanks to Julian Raschke.
|
|
- Fix all compilations warnings spotted by new compilation flags
|
|
- Major update of build system
|
|
- Calculate RTS activation time by send length
|
|
- Dynamic memory allocation of device name (closes #11)
|
|
- Add unit tests for modbus_mapping_new
|
|
- Add Visual Studio 2008 project files by oldfaber
|
|
- Fix missing argument in synopsis section of modbus_rtu_set_serial_mode
|
|
- Fix wrong constant names to create version number
|
|
- More compilation fixes for Windows by oldfaber.
|
|
- Fix wrong constant names to create version number.
|
|
Thanks to Denis Davydov.
|
|
|
|
libmodbus 3.1.0 (2012-06-22)
|
|
============================
|
|
|
|
Major changes to handle many slaves in RTU mode, non blocking connections and
|
|
RTS flow control.
|
|
|
|
- Fixes for Microsoft Visual C++ compiler
|
|
- Fixes for Windows. Thanks to oldfaber
|
|
- Return value of _modbus_tcp_pi_connect() on failure (closes #61)
|
|
- Avoid ioctl call on non-RS485 ports. Thanks to Michael Haberler
|
|
- Display node and service in PI and port in IPv4 at connection
|
|
- Return -1 on getaddrinfo error and print error in debug mode
|
|
- More robust way to establish the connection in non blocking mode
|
|
- TCP - Socket in non blocking mode by default. Thanks to Thomas Stalder
|
|
- Apply CLOEXEC flag for TCP protocol independent too (IPv6)
|
|
- New RTU receive() to ignore confirmation from other slaves (closes #18)
|
|
- Move RTU filtering in CRC check to avoid useless call to modbus_reply
|
|
- Unique transaction identifier by TCP connection
|
|
- Use accept4 with SOCK_CLOEXEC when available (Linux)
|
|
- Open fd and socket with the CLOEXEC flag when available
|
|
- Exception response on report slave ID wasn't detected (closes #27)
|
|
- Provides a way to disable the byte timeout (Alex Stapleton)
|
|
- Added slave ID check for response messages (Alex Stapleton)
|
|
- RTS flow control with modbus_rtu_set_rts and modbus_rtu_get_rts
|
|
functions by Torello Querci <tquerci@gmail.com> and Stéphane Raimbault.
|
|
|
|
libmodbus 3.0.4 (2012-05-08)
|
|
============================
|
|
|
|
- autogen.sh creates symlinks instead of copies
|
|
- Add missing m4 directory (closes #103)
|
|
- Fix alignment problem on ARMv5 platform
|
|
Thanks to Alexander Dahl
|
|
- Remove useless test on error_recovery argument
|
|
Thanks to Carlos Tangerino
|
|
|
|
libmodbus 3.0.3 (2012-05-25)
|
|
============================
|
|
|
|
- Fix another Visual C++ 2008/2010 deficiency (closes #53)
|
|
- Add -lsocket to compile on QNX
|
|
- Fix TCP PI init under Windows.
|
|
Thanks to oldfaber.
|
|
- Fix a missing free in random-test-client
|
|
Thanks again to Stefan Finzel.
|
|
- Fix OMG bug in modbus_mapping_free not freeing memory.
|
|
Thanks to Stefan Finzel for the bug report.
|
|
- Fix semicolon typo and unistd.h include under Windows.
|
|
Thanks to Andrew Kravchuk.
|
|
|
|
libmodbus 3.0.2 (2012-01-16)
|
|
============================
|
|
|
|
- Update Debian package
|
|
- Documentation fixes and additions
|
|
- Add missing C++ macros in public headers.
|
|
Thanks to Bernhard Agthe.
|
|
- Protects modbus_mapping_free against NULL argument.
|
|
Thanks to Andrea Mattia
|
|
- Fix check on file doc/libmodbus.7 in acinclude.m4 (closes #28)
|
|
- Close file descriptor when the settings don't apply in RTU.
|
|
Original patch provided by Thomas Stalder.
|
|
- unit-test.h is now generated to avoid config.h dependency.
|
|
- Request for Windows Sockets specification version 2.2 instead of 2.0
|
|
Thanks to Pavel Mazniker for the report.
|
|
|
|
libmodbus 3.0.1 (2011-07-18)
|
|
============================
|
|
|
|
- Avoid useless serial_mode integer when TIOCSRS485 isn't supported
|
|
- Fix compilation failure on Windows (RS485 support) by Tobias Doerffel
|
|
<tobias.doerffel@gmail.com>
|
|
- Properly check TIOCSRS485 define by Matthijs Kool
|
|
- Rename package to libmodbus5 to fix lintian warning
|
|
|
|
libmodbus 3.0.0 (2011-07-11)
|
|
============================
|
|
|
|
- Revert libmodbus licence from LGPLv3 to LGPLv2.1 to avoid
|
|
incompatibility with GPLv2 program. This change has been approved
|
|
by Tobias Doerffel, Florian octo Forster and Hannu Vuolasaho.
|
|
- Enable RS485 support only when available
|
|
- Export modbus_set/get_serial_mode functions on all platforms
|
|
- API change for read/write multiple registers function:
|
|
* modbus_read_and_write_registers -> modbus_write_and_read_registers
|
|
The function name was confusing because the write operation is performed
|
|
before the read. Take care to swap the arguments in the migration process.
|
|
- Documentation of modbus_write_and_read_registers, modbus_mapping_new/free,
|
|
report_slave_id. modbus_get_byte_from_bits, modbus_set_bits_from_byte(s),
|
|
modbus_[gs]et_float, modbus_reply and modbus_reply_exception.
|
|
- Enhanced report slave ID
|
|
- New RPM spec file to package documentation and development files
|
|
|
|
libmodbus 2.9.4 (2011-06-05)
|
|
============================
|
|
|
|
- IPv6 support
|
|
Make the TCP implementation "protocol independent" by Florian Forster
|
|
and Stéphane Raimbault.
|
|
- Fix compilation on Windows 7 (x64) with MinGW/MSYS and GCC 4.5
|
|
Reported by Patsy Kaye.
|
|
- Documentation of libmodbus functions with AsciiDoc (man and HTML) by Stéphane
|
|
Raimbault
|
|
- Avoid an iteration in flush function
|
|
- New functions to send and receive raw requests (modbus_send_raw_request,
|
|
modbus_receive_confirmation)
|
|
- Fix flush function of TCP backend on Windows
|
|
- API changes for server/slave:
|
|
* modbus_receive doesn't take socket/fd argument anymore
|
|
* new function modbus_set_socket to set socket/fd
|
|
- API changes for timeout functions:
|
|
* modbus_get_timeout_begin -> modbus_get_response_timeout
|
|
* modbus_set_timeout_begin -> modbus_set_response_timeout
|
|
* modbus_get_timeout_end -> modbus_get_byte_timeout
|
|
* modbus_set_timeout_end -> modbus_set_byte_timeout
|
|
- Fix longstanding limitation of server to wait forever
|
|
- New functions modbus_set/get_serial_mode by Manfred Gruber and Stéphane
|
|
Raimbault for RS485 communications
|
|
- Improved recovery mode (see modbus_set_error_recovery documentation) for
|
|
data link and protocol errors.
|
|
- Fix compilation issue with Microsoft Visual Studio 2008.
|
|
Reported by Allan Cornet.
|
|
|
|
libmodbus 2.9.3 (2011-01-14)
|
|
============================
|
|
|
|
- Major rewriting of the message reading (no more timeouts on exception)
|
|
by Stéphane Raimbault
|
|
- New function to reply to an indication with an exception message
|
|
modbus_reply_exception()
|
|
- New function modbus_get_header_length(modbus_t *ctx)
|
|
- New functions to manipulate data:
|
|
* MODBUS_GET_INT32_FROM_INT16
|
|
* MODBUS_GET_INT16_FROM_INT8
|
|
* MODBUS_SET_INT16_TO_INT8
|
|
- Fix GH-2. Read/write were swapped in _FC_READ_AND_WRITE_REGISTERS
|
|
- Install an ignore handler for SIGPIPE on *BSD
|
|
Original patch by Jason Oster.
|
|
- Fix closing of Win32 socket.
|
|
Reported by Petr Parýzek.
|
|
- Fix unit identifier not copied by the TCP server.
|
|
Reported by Antti Manninen.
|
|
- Fix missing modbus_flush() in unit tests
|
|
- Fixes for OpenBSD by Barry Grumbine and Jason Oster
|
|
|
|
|
|
libmodbus 2.9.2 (2010-12-05)
|
|
============================
|
|
|
|
- Win32 support by Tobias Doerffel
|
|
- Split source code around RTU and TCP (backends)
|
|
- Rename modbus_[listen|accept] to modbus_tcp_[listen|accept]
|
|
- Remove slave argument from modbus_new_rtu()
|
|
- Check received function code
|
|
- Fix segfault in bandwidth-server-many-up on inet_ntoa() call
|
|
- Fix unit test of report slave ID in RTU
|
|
- Fix GH-3. Remove inclusion of config.h in modbus.h
|
|
- Correctly detect if we are cross-compiling for win32 by Kirill Smelkov.
|
|
- Fix setting of the broadcast address
|
|
|
|
|
|
libmodbus 2.9.1 (2010-08-16)
|
|
============================
|
|
|
|
- Brand new API (see MIGRATION notes)!
|
|
- Remove the internal function set_message_length_tcp
|
|
- Restore slave ID (server ID) argument in functions
|
|
- Error conventions of POSIX systems and error recover
|
|
- Parity setting is now a single char ('N', 'E' or 'O')
|
|
- Report slave ID server side
|
|
- OpenBSD support by Anibal Limón.
|
|
- New read and write registers function by Hannu Vuolasaho.
|
|
- Versioning infrastructure
|
|
Inspired by the Clutter project and the work done by Florian Forster.
|
|
- Fix the broadcast constant (255 -> 0)
|
|
Reported by David Olivari.
|
|
- Fix #463299 - New functions to define the timeouts of begin and end of trame
|
|
Original patch by Sisyph (eric-paul).
|
|
- Fix #591142 - Slave id check should be disabled in TCP connection
|
|
Reported by aladdinwu.
|
|
|
|
|
|
libmodbus 2.1.0 (2010-03-24)
|
|
============================
|
|
|
|
- New API to read and write float values by Stéphane Raimbault and Florian
|
|
Forster.
|
|
- New API for slave server (see MIGRATION)
|
|
- New slave server able to handle multiple connections
|
|
- Slave only replies to broadcast queries or queries with its slave ID
|
|
- Improved Modbus protocol conformance
|
|
- modbus_param_t is smaller (2 int removed)
|
|
- Better error management and SIGPIPE signal is blocked
|
|
- Faster
|
|
- Fix #333455 - Cygwin IPTOS_LOWDELAY not supported on cygwin
|
|
Reported by Jeff Laughlin and Yishin Li.
|
|
- Fix #375926 - modbus.c:164: error: `MSG_DONTWAIT' undeclared
|
|
Reported and tested by Yishin Li.
|
|
- Fix #378981 - CRC error on RTU response doesn't return negative value
|
|
Reported by Henrik Munktell.
|
|
- Fix report slave ID request
|
|
Patch (bzr) provided by Paul Fertser.
|
|
- Fix #425604 - Conditional jump or move depends on uninitialised value(s)
|
|
Occurs on first occurence of slave timeout.
|
|
Reported by Henrik Munktell.
|
|
- Fix #457200 - FreeBSD support
|
|
Patch provided by Norbert Koch.
|
|
|
|
Other changes:
|
|
|
|
- The code is now published and developed on
|
|
http://github.com/stephane/libmodbus
|
|
- Waf support has been removed
|
|
|
|
|
|
libmodbus 2.0.3 (2009-03-22)
|
|
============================
|
|
|
|
- Fix CRC error when a slave RTU send a response.
|
|
Thanks to Justin Carroll to have reported and tested my patch.
|
|
- Remove an assignment in compute_response_length()
|
|
- Remove duplicate counter in read_io_status()
|
|
- Fix #274511 reported by 'Kylesch'
|
|
Invalid error check in modbus_init_listen_tcp
|
|
|
|
|
|
libmodbus 2.0.2 (2008-08-10)
|
|
============================
|
|
- Fix a bug reported by email by Davide Pippa
|
|
The function modbus_receive must check the number of values
|
|
indicated in the response accordingly to the query.
|
|
- Fix #241006 reported by Jesus Hernandez Tapia
|
|
modbus_check_response() crashes on an invalid exception code
|
|
- Reduce the number of function calls (read_reg_response and
|
|
preset_response have been removed)
|
|
- Add a new unit test for bad response
|
|
- Catch the timeout even if the length is equal to a exception trame
|
|
- Test only msg_length_computed on change
|
|
- Many comments and cleanups
|
|
|
|
|
|
libmodbus 2.0.1 (2008-07-02)
|
|
============================
|
|
|
|
- Include libmodbus.spec in the tarball
|
|
- Fix #241006 reported by Jesus Hernandez Tapia
|
|
modbus_check_response() crashes on an invalid exception code
|
|
|
|
|
|
libmodbus 2.0.0 (2008-05-18)
|
|
============================
|
|
|
|
- Slave API
|
|
https://blueprints.launchpad.net/libmodbus/+spec/slave-api
|
|
- No more glib dependency
|
|
https://blueprints.launchpad.net/libmodbus/+spec/glib-dependency
|
|
- Unit testing and many test programs
|
|
- Waf build support
|
|
https://blueprints.launchpad.net/libmodbus/+spec/waf-support
|
|
- MacOS X support by Matthew Butch
|
|
https://blueprints.launchpad.net/libmodbus/+spec/macosx-support
|
|
- Unit testing (unit-test-slave and unit-test-master)
|
|
- Port number is now defined at initialisation by Dirk Reusch
|
|
- Better memory management (uint8_t *data and packing of
|
|
modbus_param_t)
|
|
- Better error management
|
|
- Declare many static functions and const arrays
|
|
- Enhance an integer division
|
|
- The GNU licences LGPL and GPL are in version 3
|
|
- Debian and RPM packages (#224496)
|
|
- Many cleanups
|
|
- Fix #159443 reported by Stefan Bisanz
|
|
Index of incoming data in force multiple coils function
|
|
- Fix #161989 reported by Konstantinos Togias
|
|
Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
|
|
fit to modbus_param_t -> device char[11] var.
|
|
- Fix #188189 reported by Chris Hellyar
|
|
Compute_response_size() no entry for read_input_status()
|
|
- Fix #191039 reported by Todd Denniston
|
|
modbus.h is not installed at prefix.
|
|
- Fix #211460 reported by Todd Denniston
|
|
With TCP, automatic reconnect on error may not be desired.
|
|
- Fix #224485 reported by Todd Denniston
|
|
libmodbus does not link with c++ code.
|
|
- Fix #224496 reported by Todd Denniston
|
|
It is easier to install on rpm based systems with a spec file.
|
|
|
|
|
|
libmodbus 1.2.5 (2008-05-18)
|
|
============================
|
|
|
|
- Fix #224485 reported by Todd Denniston
|
|
libmodbus does not link with c++ code.
|
|
|
|
|
|
libmodbus 1.2.4 (2008-03-14)
|
|
============================
|
|
|
|
- Fix #191039 reported by Todd Denniston
|
|
modbus.h is not installed at prefix.
|
|
|
|
|
|
libmodbus 1.2.3 (2008-02-03)
|
|
============================
|
|
|
|
- Fix #188189 reported by Chris Hellyar
|
|
Compute_response_size() no entry for read_input_status()
|
|
- Fix #181887 reported by Jesus Hernandez Tapia.
|
|
Slave address in build_request_packet_tcp() is hardcoded as 0xFF.
|
|
|
|
|
|
libmodbus 1.2.2 (2007-11-12)
|
|
============================
|
|
|
|
- Fix #161989 reported by Konstantinos Togias
|
|
Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
|
|
fit to modbus_param_t -> device char[11] var.
|
|
- Structure is also bit better 'packed' to conserve memory (see the
|
|
trunk for a real enhancement).
|
|
|
|
|
|
libmodbus 1.2.1 (2007-11-02)
|
|
============================
|
|
|
|
- Fix #159443 reported by Stefan Bisanz
|
|
Index of incoming data in force multiple coils function
|
|
- Deleted useless code in check_crc16()
|
|
- Untabify source code
|
|
- Changed author's email to Stéphane Raimbault
|
|
|
|
|
|
libmodbus 1.2.0 (2007-05-10)
|
|
============================
|
|
|
|
- FIX Compilation GCC-4.0
|
|
- Project name in autogen.sh
|